Thermal Dynamics Victor Auto-Cut 300 XT Manuel D'instructions page 109

Générateur de coupage à l'arc plasma
Table des Matières

Publicité

6
J100 -- 30 CKT RIBBON
ELECTRODE (-)
WORK (+)
OUTPUT
J100 -- 30 CKT RIBBON
ELECTRODE (-)
WORK (+)
OUTPUT
J100 -- 30 CKT RIBBON
ELECTRODE (-)
WORK (+)
OUTPUT
J100 -- 30 CKT RIBBON
ELECTRODE (-)
WORK (+)
OUTPUT
J100 -- 30 CKT RIBBON
ELECTRODE (-)
WORK (+)
OUTPUT
Revision
Rev
00
Initial Design
0
1
A
d
d
F
2
02
Add T1 Inrush Ckt
6
Manuel n° 0-5290FR
7
TO CCM
CPU PCB J36
(Sht 2, C3)
(49F)
5
4
3
(51F)
2
1
J102B
TO CCM
CPU PCB
J35
(Sht 2, C3)
(49E)
5
4
INVERTER
3
J40
2
(50)
1
5
4
J102A
3
2
1
(51F)
019X501600
J42
10 ckt Ribbon
TO J3 on RELAY PCB
(Sht 2, A5)
To J24 on I-O PCB
(Sht 2, D3)
TO CCM
CPU PCB
L1
J33
(Sht 2, C3)
J102A
(49C)
5
(51)
4
3
2
1
TO CCM
J46-M
CPU PCB
J32
J46-F
(Sht 2, C3)
J102B
(49B)
5
4
TO J1 on RELAY PCB
3
2
(Sht 2, B9)
1
TO CCM
CPU PCB
J31
(Sht 2, C3)
RIBBON CABLE 30 ckt.
CCM (J31-36) - INVERTER (J100)
J102A
(49A)
1 Ready
5
2 Ready_RTN
4
3
3 INVERTER_FLT
(50)
2
4 INVERTER_FLT_RTN
1
5 OVERTEMP_FLT
6 OVERTEMP_FLT_RTN
7 SPARE
8 SPARE_RTN
9 VAC_SELA
10 1VAC_SELB
11 1OUT_COM (+5V)
12 IS_IDA
13 IS_IDB
14 IS_IDC
15 ENABLE
16 ENABLE_RTN
17 START2
18 START2_RTN
19 215 OHM TO COMM
20 SYNC
21 SYNC/
22 215 OHM TO COMM
23 NC
24 COMM
25 DEMAND +
26 DEMAND-
27 COMM
28 CURRENT+
29 CURRENT-
30 COMM
Date
Revision
By
Rev
DAT
10/03/2012
D
A
T
1
1
2 /
1
2 /
0
1
2
DAT
2/18/2013
7
8
9
(49)
J43
ELECTRODE
PILOT PCB
J44
EARTH GROUND
1
(49)
J41
CHASSIS GND
2
1
TIP
(52)
J45
TO I/O BOARD
(53)
TIP VOLTS
WORK
ARC VOLTS
(55)
(51)
HCT1
Hall Effect Sensor
(51)
J16
(49)
(52)
(51)
(60)
(56)
AC 120V- TB4-4
(61)
(57)
AC 120V- Ret- TB4-3
(62)
(58)
AC 24V-TB4-2
(63)
(59)
AC 24V- Ret -TB4-1
(J10 Sht 2, B8)
RIBBON CABLE 40 ckt CCM (J23) - RELAY PCB (J4)
1
COMMON
2 /1TORCH START *
3
NA
4 /1TORCH GAS SOL ON *
5 /MAIN TORCH IDLE *
6 /1TORCH PRESS OK *
7
FLOW SENSOR (pulses)
8
LOW COOLANT FLOW
9
COOLANT LEVEL OK
10 COMMON
11 NA
12 /PLASMA ENABLE-HMI
13 /COOLANT PUMP ON
14 COMMON
15 /PILOT ENABLE
16 /RAS ON
17 /CONTACTORS ON
18 COMMON
19 /COOLANT FANS ON
20 /1TORCH CONTACTOR ON *
21 /PLASMA ENABLE RELAY
22 COMMON
23 PILOT CURRENT SIG-
24 NC
25 PILOT CURRENT SIG+
26 COMMON
27 WORK CURRENT SIG-
28 WORK CURRENT SIG+
29 NC
30 AMBIENT TEMP
31 COOLANT TEMP
* Used with 1 Torch Option
Date
By
The information contained herein is proprietary to Victor Technologies.
Not for release, reproduction or distribution without written consent.
Title
SCHEMATIC
Auto-Cut XT 300A CE 380-415 VAC
8
9
A-33
Auto-cut 300 Xt
10
A
L3
TORCH
1
RAS
PILOT
1
B
SHIELD
(-)
CHASSIS GND
(+)
Tip
WORK
(+)
Work
1
C
TB4
ARC VOLTS (TORCH)
7
TIP VOLTS (PILOT)
6
WORK
5
4
120 VAC @ 100 ma.
3
2
24 VAC @ 1A
1
32 COMMON
33 -15 VDC
34 COMMON
D
35 24 VDC
36 COMMON
37 24 VDC
38 COMMON
39 24 VDC
40 COMMON
RIBBON CABLE 16 ckt
CCM ( J37) - DISPLAY
PCB (J17)
1,3,5,7
24 VDC
2,4,6,8
COMMON
9,10
NC
11-16
SERIAL DATA
RIBBON CABLE 10 ckt
E
RELAY PCB (J3) – PILOT PCB (J42)
1,2
24 VAC
3,4,7,10
COMMON
5
PILOT ENABLE +
6
PILOT ENABLE –
8
PILOT CURRENT SIG –
9
PILOT CURRENT SIG +
Art # A-11956
Victor Technologies Headquarters
16052 Swingley Ridge Road, Suite 300
St Louis, Missouri 63017 USA
F
Date Printed
Date Revised
4/8/2013
3/18/2013
Drawn
Date
DAT
10/04/2012
Size
Sheet
C
1
2
of
Drawing Number
042X1351
10
ANNEXE