Troubleshooting

Problem
Bender will not operate.
Bends are overbent a few
degrees.
Bends are underbent a few
degrees.
Greenlee Tools, Inc.
Probable Cause
No voltage.
Too much squeeze on 1-1/2" or
2" EMT or IMC conduit.
Unusual conduit characteristics.
Too little squeeze on 1-1/2" or
2" EMT or IMC conduit.
Unusual conduit characteristics.
29
555C Electric Bender Classic
Possible Remedy
Check supply voltage circuit
operation.
Check that switch is on.
Back squeeze off per adjustment
instructions.
Bend smaller angle to compensate.
Increase squeeze per adjustment
instructions.
Bend larger angle to compensate.