ELECTRICAL WIRING

Connect the power base wires to the power supply and load using twist-on wire connectors for copper
wires (see diagram below), as supplied in the packaging box.
• Connect the power line to the thermostat line cables marked L1 and L2.
• Connect the heating cable to the thermostat load cables marked Load 1 and Load 2. (max 15 amps)
• Connect to 1st wire of floor sensor to terminal 1 (colour not important)
• Connect to 2nd wire of floor sensor to terminal 2 (colour not important)
NOTE: All cables and connections must be carried out by a qualified electrician and must conform to
the local electrical code.
BARE COPPER
(ground)
Caution: High Voltage
Disconnect power supply
before servicing.
AVERTISSEMENT:
HAUTE TENSION
WARMUP
HEATER
15A MAX.
Caution: High Voltage
Disconnect power supply
before servicing.
AVERTISSEMENT:
HAUTE TENSION
24/7 Technical hotline - Ligne d'assistance technique - Línea de asistencia técnica
US 1.888.927.6333 / CA 1.888.592.7687
Do not use where exposed to rain
Ne pas utiliser dans un emplacement mouillé
L1-LOAD-L2
L2
LINE
L1
1
2 3
EXT
SENSOR
(NO POLARITY)
For mounting on an outlet box only
LINE
RED
LINE
L1-LOAD-L2
BLACK
LOAD
RED
LOAD
BLACK
Do not use where exposed to rain
Ne pas utiliser dans un emplacement mouillé
L1-LOAD-L2
1
2 3
For mounting on an outlet box only
L2
LINE
L1
1
2
3
EXT
SENSOR
(NO POLARITY)
FLOOR
SENSOR
L2
LINE
L1
EXT
SENSOR
(NO POLARITY)
7