Télécharger Imprimer la page

Fein Turbo I Mode D'emploi page 17

Masquer les pouces Voir aussi pour Turbo I:

Publicité

Les langues disponibles

Les langues disponibles

Regulating the air flow (figure 10).
The air flow can be variably increased or
decreased.
To increase the air flow, turn the air-volume
regulator counterclockwise.
To decrease the air flow, turn the air-volume
regulator clockwise.
Cleaning the sensors (figure 11).
After completion of the wet vacuuming, clean
the sensors and their intermediate area using
a brush.
Further notes.
For wet vacuuming, use the flat-fold filter
only; do not use a fleece filter bag.
For dry vacuuming, always use the flat-fold fil-
ter and the fleece filter bag.
Never vacuum without the
CAUTION
flat-fold filter, as otherwise
the motor will become damaged and
increased output of fine dust may pose a haz-
ard to one's health. For vacuuming fine dust,
a fleece filter bag must additionally be used.
When the exhaust air is circulated, an ade-
quate ventilation rate L must be given. The
recirculated flow rate must not exceed 50 %
(max.) of the fresh air volume (volume of
space x ventilation rate L
ventilation measures, the following applies:
-1
L
= 1 h
.
w
). Without special
w
Fig. 10
Tool adapter
Vacuum hose
Fig. 11
Sensor
When wet vacuuming electrically-conductive
liquids, the vacuum cleaner is automatically
switched off after reaching the maximum fill-
ing height (automatic shut-off). Pull the mains
plug from the socket outlet and empty the
container.
When wet vacuuming electrically non-con-
ductive liquids, the vacuum cleaner is not
automatically switched off after reaching the
maximum filling height. Empty the container
in time.
When foam comes out of the vacuum
cleaner, switch the vacuum cleaner off imme-
diately and empty the container.
en
17
Tool adapter
Vacuum hose

Publicité

loading

Ce manuel est également adapté pour:

Turbo iiTurbo ii s21069 20 279 20 2858694