5.1. CASE OF MOTORS WITHOUT POSITION FEEDBACK

Before switching on the RT COM, set switch SW1 to "12h. ON".
Switch on the unit,
Check that:
The jumper "S4" is set to "OFF" or "ON".
The "SECTEUR" indicator, LD1, lights.
The "CODE" indicator, LD3, flashes as the synchronization code is received.
The "SYNC" indicator, LD2, lights, after approximately 15 seconds when receiving
IRIG.B/AFNOR code, and
After 3 to 4 minutes in case of radio reception. (if this does not happen, adjust or
move the antenna)
The motor is stopped,
Fit the hands and set them to midday.
Set switch SW1 to "OFF".
From now on, the time of the clock will be set automatically. This occurs as soon as the
"SYNC" indicator, LD2, lights.
If the time is after 11 or 23, the clock remains stopped and waits for midday or mid¬night
and then restarts in normal forward operation.
In all other cases, the time of the clock will be reset in fast forward operation at a rate of 1
minute every 3 or 5 seconds, depending on the model.