Description; Fixing The Case - Gorgy Timing RADIO TIMING COM Mode D'emploi

Boîtier de commande pour horloge grande dimension
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The RT COM is a control unit that receives a radio or IRIG.B/AFNOR NFS87500 time
code. It is designed to automatically reset the time of a large clock that has a 230
VAC synchronous motor and sensors to detect the position of the hands.
Operation available depending on the type of motor.
Standard version: Pulse width 5.5 seconds
Standard 2 engines
Without needle detection
1 minute motor synchro
Other version available: pulse width 8 seconds
Standard 2 engines
Note: Version requested when ordering
Unscrew the 4 screws that close the cover:
it is fixed using 4 M4 screws in accordance with the above diagram.
16
Dimension
76
Wiring
LD1
Secteur/
Power supply
1A
Relays
Fus.
P1
P2
COM P1
230V
P2
or
or
A
B
Motor
230V
control
Input
2. FIXING
130
113,5
LD3
LD2
Code
Sync.
Radio
IRIGB /
ON
AFNOR
S4
option card
OFF
ON
OFF
8
SW1
on
off
1
MAN
SW2
P1
MAN
CODE
230V
12Hrs
P2
Input
Min
GND
AFNOR code
Position
or
sensor
Antenna
input
inputs

1. DESCRIPTION

THE CASE
Présentation
175
MDE-RTcom-3024V1.5
75
125

Publicité

Chapitres

Table des Matières
loading

Table des Matières