Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.3

GENERAL INFORMATION

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
Altitude (FT)
Max. Input (BTU/HR)
Min. Inlet Gas Supply Pressure
Max. Inlet Gas Supply
Pressure
Manifold Pressure (Under Flow
Conditions)
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is suitable for mobile
home installation.
No external electricity (110 volts or 24 volts) is required for the gas millivolt system operation.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be
expected.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and shall be installed.
QUALITY!
RATES AND EFFICIENCIES
B35
NG
0-4,500
0-4500
20,000
20,000
4.5" (11mb) w.c.
11" (27mb) w.c.
7" (17mb) w.c.
13" (32mb) w.c.
3.5" (9mb) w.c.
10" (25mb) w.c.
LP
NG
0-4,500
25,000
4.5" (11mb) w.c.
7" (17mb) w.c.
3.5" (9mb) w.c.
7
EN
B42
LP
0-4500
25,000
11" (27mb) w.c.
13" (32mb) w.c.
10" (25mb) w.c.
W415-1399 / 09.30.14

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

B35nteB42ntB42nteB35ptB35pteB42pt ... Afficher tout

Table des Matières