Maintenance; Replaceable Parts - Franklin Electric SUBDRIVE UTILITY UT2W 5870202003 Serie Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MAINTENANCE

The screen(s) should be checked occasionally and cleaned of debris to ensure proper drive function. As the screen becomes full/blocked,
the SubDrive Utility will reduce output power to avoid excessive internal heat. This may result in reduced water delivery.
Fan Screen Removal
The fan screen is located on the bottom of the drive enclosure covering the fan grill.
1.
Remove the center screw holding the fan screen in place (if installed).
CAUTION: If the plastic fan screen holder is installed with a screw, the screen holder is required
to be installed at all times during drive operation.
2. Gently squeeze the retaining clips on the sides of the screen and pull away from the drive.
3. Clear debris from the plastic screen frame and metal mesh screen.
4. Reinstall the plastic screen frame. Ensure the metal mesh screen is properly retained between the drive enclosure and plastic screen frame.
5. Reinstall the center screw and tighten to 1.5 in-lbs (0.17 Nm) (if previously installed).
Lid Screen Removal
The lid screen is located inside the drive cover in the exhaust vent area.
1.
Remove power from the drive and allow 5 minutes for internal voltage to dissipate.
2. Remove the drive cover.
3. Remove the two screen retaining screws on the outside of the lid in the exhaust vent area.
4. Remove the plastic screen retainer from the inside of the cover in the recessed exhaust vent area.
5. Remove the metal mesh screen that is placed between the recessed exhaust vent cavity and the plastic screen retainer.
6. Clear debris from the plastic screen retainer and metal mesh screen.
7.
Reinstall the metal mesh screen and plastic screen retainer.
8. Reinstall the two retaining screws and tighten to 5 in-lbs (0.55 Nm).
9. Reinstall the drive cover.

REPLACEABLE PARTS

Cooling Fan
In the event that the cooling fan fails and results in an occurrence of frequent Overheated Drive faults (Fault Code 7), the fan is able to be replaced.
See the "Accessories" section on page 26 for information regarding NEMA 3R fan replacement kits.
Air Screens
In the event that the air screens are damaged or lost, replacement screens are available. See the "Accessories" section on page 26 for
information regarding air screen kits.