Greenlee DML-54 Manuel D'instructions page 18

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Accuracy (cont'd)
AC Voltage
Range
50 Hz - 60 Hz
± (0.5% + 0.03 mV) ± (0.8% + 0.03 mV)
49.99 mV
± (0.5% + 0.3 mV)
499.9 mV
± (0.5% + 0.003 V)
4.999 V
± (0.5% + 0.03 V)
49.99 V
± (0.5% + 0.3 V)
499.9 V
± (0.5% + 3 V)
1000 V
* Specified from 30% to 100% of range.
DC Voltage
Range
± (0.12% + 0.02 mV)
49.99 mV
± (0.06% +0.2 mV)
499.9 mV
± (0.08% + 0.002 V)
4.999 V
± (0.08% + 0.02 V)
49.99 V
± (0.08% + 0.2 V)
499.9 V
1000 V
18
Accuracy at
± (0.8% + 0.3 mV)
± (1.0% + 0.004 V)
± (1.0% + 0.04 V)
Accuracy
± (0.08% + 2 V)
Accuracy at
40 Hz - 500 Hz
± (1.0% + 0.4 V)
± (1.2% + 4 V)
Input Impedance
10 MΩ, 44 pF nominal
10 MΩ, 16 pF nominal
Accuracy at
500 Hz to 20 kHz
0.5 dB*
44 pF nominal
0.5 dB*
3 dB*
3 dB*
16 pF nominal
3 dB*
unspecified
Input
Impedance
10 MΩ,
10 MΩ,

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dml-430

Table des Matières