THANK YOU FOR YOUR PURCHASING DUSTBANE'S ENVIRO FLEX!
Please use this equipment carefully and observe all warnings and cautions.
The package should contain:
Proportioner unit
Supply tubing
Discharge tubes

Important Safety Instructions

WEAR protective clothing and eyewear when dispensing chemicals or other materials or when working in the vicinity of all
chemicals, filling or emptying equipment, or changing metering tips.
ALWAYS observe safety and handling instructions of the chemical manufacturer.
ALWAYS direct discharge away from you or other persons or into approved containers.
ALWAYS dispense cleaners and chemicals in accordance with manufacturer's instructions. Exercise CAUTION when maintaining
your equipment.
ALWAYS reassemble equipment according to instruction procedures. Be sure all components are firmly screwed or latched
into position.
ATTACH only to tapwater outlets (85 PSI maximum)
KEEP equipment clean to maintain proper operation.
NOTE if the unit is used to fill a sink or discharge hose can be placed into a sink, the unit must be mounted so that the bottom
of the cabinet is above the overflow rim of the sink.
Installation and Operation:
1.
Find suitable place close to water source for unit. Remove dispenser cover by depressing the button on the top of the dispenser and pull the
cover forward and off . Do not mount dispenser more than 6 feet (1.8 meters) above the bottom of the concentrate container, nor below the
highest concentrate level (never mount your concentrate higher than the proportioner).
2.
Remove mounting rail from the back of dispenser by rotating the black lock bars, located on the inside back of dispenser, rotate toward the
outside of the dispenser.
3.
Hold mounting rail level against wall and mark (2) mounting holes. Drill 9/32" hole and install anchors in wall. Secure mounting rail to wall with
screws provided.
NOTE: Distance from top of mounting rail to top of dispenser is 2.5". If mounting dispenser under cabinet or shelf be sure to leave clearance
to access button at the top of dispenser for removal of cover.
4.
Place the dispenser over the mounting rail aligning the bosses around the mounting screws with the large holes in the dispenser back. Rotate
the locking tabs toward the center of the dispenser to secure the dispenser to the wall.
NOTE: IT IS REQUIRED THAT A SAFETY SCREW BE INSTALLED. Mark the wall using one of the lower holes in the back of the dispenser.
Remove the dispenser from the mounting rail by rotating locking tabs toward the outside of the dispenser then lifting the dispenser off of
the mounting rail. Drill 9/32" hole and install anchor. Reattach the dispenser to the mounting rail (see #4). Install security screw through
the back of the dispenser into anchor in the wall.
5.
Select metering tips (up to 4) for the QDV valve. (see next two sections) Push each tip firmly into a separate hose barb extending from the
selector valve. A tip with no hole (clear plastic) can be used to block any valve port being used. (this may be used for dispensing water only).
6.
Install four 5.5" precut lengths of tubing onto the four hose barb ports of the QDV valve. Insert four in-line check valves, with arrows pointing
toward the QDV valve, into the open ends of the pre-cut lengths of tubing.
7.
Cut supply tubing provided into separate supply tubes for each product to be dispensed. Supply tubes should reach from in-line check valve
barb to bottom of concentrate container. Push one end of supply tube over the hose barb of the in-line check valve. Slide weight over end of
each tube, then install foot strainers on ends of supply tubes before placing into concentrate containers. REMEMBER TO CHECK FOOT STRAINERS
PERIODICALLY FOR CLOGGING: CLEAN IF NECESSARY.
8.
Connect water supply hose of at least 3/8"ID to water inlet swivel. (Minimum 25 PSI pressure, with water running, is required for proper
operation.) Connect opposite end of hose to water supply. Turn water supply on. Replace dispenser cover.
9.
A short discharge tube is used with the 1GPM eductor; minimum tube length is 8 inches (20 cm) for proper operation. Longer tubes (6 feet)are
used with a 3.5 GPM eductor. Do not remove the flooding rings from inside the tubes. Slide end of tube with flooding ring over eductor discharge
outlet. (Repeat for all discharge outlets.) Hooks may be installed on longer tubes to allow discharge tube to conveniently hang from dispenser
when not in use.
10.
To operate button fill units, depress button to dispense product, release button to stop flow. IF YOU WISH TO BE ABLE TO LOCK THE BUTTON IN
THE "ON" POSITION: Depress button and slide button lock up, TO UNLOCK, DEPRESS BUTTON AND RELEASE.
11.
Bottle fill activates by inserting a spray bottle over the discharge tube and lifting lever until flow starts. To stop flow, lower bottle off discharge
tube. To operate units with remote bucket fill hold and depress lever of gun. To stop flow release lever. IF YOU WISH TO BE ABLE TO LOCK THE
REMOTE BUCKET FILL IN THE "ON" POSITION: Depress lever and position lock on bottom of lever, TO UNLOCK, DEPRESS LEVER AND RELEASE.