Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Installation & Instructions for use
AeroFlow Heater
1.General
Keep these documents in a safe place. Should the property be sold please pass them on
to the next owner. The appliance is only suitable for heating the room for which it was
specified.
Changing the mains wire or altering the appliances in any way invalidates the guarantee.
A damaged appliance (for example broken mains wire) should not be used until a safety
check has been conducted by a competent electrician.
In case of defect, or suspected defect, the appliance should be isolated from the mains
electricity supply and be inspected by a competent electrician.
Do not cover the heater, so doing could become a Fire risk.
Caution! Outer Panel becomes hot when in use, do not place any articles against the
panels.
Do not use the appliance without consideration of nearby children. (Use guards where
appropriate) Children should be monitored, to ensure that they do not play or tamper with
the appliance.
The appliance needs to be installed so that the temperature controller, switch and wires
cannot be reached from a shower or bath. The latest regulations VDE 0100 part 701 must
be used
the heater is, when mounted correctly, IPX3 proofed (excluding models with integrated
thermostat)
Materials which are flammable such as glue or floor covering should only be used in the
vicinity of the heater after the heater cools down to room temperature.
The heater should not be installed directly under a wall socket.
This appliance should not be operated by persons, (including children) with limited
physical, sensory, limited mental abilities or insufficient experience and/or insufficient
knowledge, unless they are supervised or instructed by a person that is responsible for
their safety.
2. Installation, Minimum distances
The heaters must be installed horizontally on the wall. Fitting in any other way or position
will invalidate the guarantee.
The appliances should be installed so that flammable items cannot catch fire. Caution
must be exercised when installing onto a wooden wall or wood clad surface, particularly
where damp is present. The heat from the appliance may cause wood to warp.
The minimum distances from particularly highly flammable items such as curtains,
upholstered furniture polished tables etc. must be strictly adhered to.
Please make sure that the appliance can radiate heat into the room. (Not be obstructed by
furniture, drawn curtains etc.
Always install wall sockets below or to the side (with safety clearance) of the heater to
prevent the socket and cables overheating.
You must use suitable screws and plugs for the wall type. (The enclosed fixings are for
fixing to solid masonry walls, seek advise for other wall types.)
For positioning of the drill holes for the wall brackets, see installation drawing.
Only the enclosed wall brackets should be used.
3. Electrical Connection
The heater is supplied for use with a 13 amp socket. Where the installation includes fitting
to a fused spur, this work must be carried out by a suitably qualified electrician.
To regulate the room temperature the heater is fitted with either an integral thermostat or
radio frequency controls. Heaters supplied without these controls must be connected to a
suitable room thermostat as shown in the sketch below. Do not site thermostats where
another source of heat can influence the performance. i.e. in direct sunlight, near other
heating appliances, near the rear of a television set etc.
Damage to the main heater cable must be changed by the manufacturer, his service
agent or other qualified persons to avoid danger.
Use heater only
with thermostat !
4. Using the heater
The heater must be controlled by a room thermostat, either supplied with the heater or one
fitted by a qualified electrician.
The higher the setting of the thermostat will result in longer heating times, higher room
temperature and higher running costs. Please take notice of the instructions of the
thermostat.
During the initial operation of the heater it is possible that the final drying of the internal
clay slabs may cause a smell for a little while. This is normal. Please ensure that the room
is ventilated during this time.
5. Overheat protection
For your safety the heater is supplied with integrated overheat protection.
In the case of incorrect use of the heater (for example due to covering or fluid spillage) the
appliance will turn off automatically. As described in point 1.
The heater should not be covered for any reason. It should never be used for drying
towels or clothing. The user is responsible for all damage caused to the thermal switches
and the cost of replacement.
6. Failure
Should the heater fail to heat up, please check that the switch of the thermostat is
adjusted to the required temperature. (NOT in the off position)
Check that the heater is connected to the electricity supply.
Check that the socket is working and switched on.
Check that there is a fuse in the plug and that the fuse is working.
If, after these checks the heater fails to heat up, please report to your technical workshop
or to the nearest Service station for Electrorad appliances.
To handle your request we will need the serial number of the heater, which you will find on
the type plate.
7. Service
In case of service, only Electrorad or their contractual partners are permitted to open the
heater.
8. Cleaning of the heater
The heater must be turned off and completely cooled down. Turn the switch on the
thermostat to the "OFF"-position or the wheel to the minimum temperature. The hot
surface must not be cooled down with water.
The outside can be cleaned and dried by a smooth, damp cloth. Do not use any abrasive
powder or other chemicals, these could damage the surface.
5
Roomthermostat
L1
L1
Socket
PE
PE
N
N
9. Warranty
There is a 30 year manufacturers function and parts guarantee for the basic unit, and 2
year for the thermostat.
for 2 years in accordance with warranty details. We are not responsible under guarantee
when the function of the appliance is affected due to any damage as a result of
inappropriate handling, use of force, normal abrasion, repair attempts by unauthorized
persons, transport, misuse, disregard of usage and installation instructions, chemical
and/or electrochemical influence or improper operation.
10. Disposal instructions
Thermotec products are recyclable. Please list your product at the end of
useful life to disposal (local sites).
The heater should be installed under a window or on an outer wall (not mandatory).
Attention should be paid to the minimum distance of 8cm to the floor or floor-covering
surface, 10cm from walls to the side of the heater and 10cm from a window-board or
shelf. DO NOT install the heater directly under a wall socket.
The heater should have clear and open access to the room, not positioned behind
furniture or where it will be covered by full length curtains.
1. Fix the support posts to the wall, using the fixings provided. The open part of the
wall brackets facing the wall.
2. Hook the larger of the two flat metal support hooks into the slots at the bottom of the
wall brackets with the square section facing upwards.
3. Lift the heater onto the bottom brackets with the brackets between the heater ribs,
equal distance from either end of the heater and hold the heater leaning slightly
away from the wall.
4. Hook the other metal support hooks into the wall brackets into the slot at the top of
the wall bracket with the square section pointing downwards.
5. Lean the heater towards the wall
6. Clip the two top brackets onto the top of the heater between the ribs of the heater.
Replace the heater cover
More pics on page 13!
Flute
Flute
X
Hook
Abb.1
10cm
Abb. 2
8cm
Typ
MINI 650 (TFLH-1)
COMPACT 1000 / 1300
TFLH 2-3
MIDI 1500 / 1950
TFLH 4-5
MAXI 2000 / 2450
1066 mm
TFLH 6-7
SLIM 1200
TFLH 12
SLIM 2000
1366 mm
TFLH 14
SLIM 1600 Tall
TFLH-10
232mm
232mm
Upwards
Hook

Dimensions

X
190mm
X
Y
232 mm
405 mm
466 mm
405 mm
766 mm
405 mm
405 mm
766 mm
105 mm
105 mm
3
2
1
Down
90mm
Y
90mm

Publicité

loading