Note
During fitting, the adapter must be fitted as a damper between the stopcock and flow meter. Take note of the
arrow marked on the flow meter showing the correct direction of flow. Use the correct seals appropriate for the
pipe diameter only. In this way water can flow freely without added turbulence through the measuring area.
Correct flow measurement can only be achieved if these instructions are complied with.
Close the gas mains stopcock if the machine is connected to a gas supply.
Disconnect the machine from the electrical mains and the gas supply if appropriate. Ensure utilities cannot
be switched on again in error.
Connect the flow meter to a 1 stopcock using the reducing bush, pipe nipple and reducing piece, Fig. 1.
Connect the water intake hose to the flow meter.
Remove the cover plate from the electrical connection on the rear of the machine.
Connect the flow meter connections in accordance with the multifunction module 07 wiring diagram.
Refit the cover plate over the electrical connection on the rear of the machine.
Check the newly fitted parts for leaks.
Carry out appropriate electrical safety checks.
Reconnect the machine to the electrical supply and, if appropriate, the gas supply. Switch the utilities on.
Register the module 7 via the service mode depending on the software ID, e.g. Service level Service
settings Module registration MFM with coding 7 Activate disk symbol to save the setting. Or Service
level Service settings Module registration EZL with coding 7 Module registration? OK
button Activate disk symbol to save the setting.
Activate flow meter measuring for the appropriate flow meter (here e.g. number 1) for the control via the
service mode: Service level Service settings Basic settings Water intake Flow meter Flow meter
1: No Yes Back symbol (select Yes on flow meter level) Back symbol (on flow meter level) Back
symbol (on water intake level) Activate disk symbol to save the flow meter 1 setting.
To quit the service mode, switch off the machine.
Carry out a functional check, e.g. with the start of a programme. This programme should take in water via the
appropriate flow meter. If the machine display does not indicate a fault, the flow meter is in order.