2.2.17. CODE DE SIGNALISATION ANOMALIES
CODE
ANOMALIES
E01
BLOCAGE FLAMME
E02
THERMOSTAT
SÉCURITÉ (95°C)
CAUSE POSSIBLE
LA FLAMME NE S'ALLUME PAS
MANQUE DE GAZ;
ÉLECTRODES D'ALLUMAGE
QUI FONT MASSE OU
DÉFECTUEUSES;
VANNE GAZ DÉFECTUEUX;
ALLUMAGE LENT
RÉGLÉ TROP BAS;
PRESSION D'ENTRÉE
BLOC TROP ÉLEVÉE
(UNIQUEMENT POUR LES
CHAUDIÈRES G.P.L.).
LA FLAMME S'ALLUME
ÉLECTRODE DE DÉTECTION
DÉFECTUEUSE;
CÂBLE ÉLECTRODE DE
DÉTECTION DÉBRANCHÉ;
COURANT ÉLECTRIQUE
PHASE-PHASE.
DE
CÂBLE DU THERMOSTAT
DÉFECTUEUX OU
DÉBRANCHÉ;
THERMOSTAT
DÉFECTUEUX.
2. ENTRETIEN
SOLUTION
VÉRIFIER L'ALIMENTATION GAZ;
LA REMPLACER;
LA REMPLACER;
RÉGLAGE DU MINIMUM OU DE
L'ALLUMAGE LENT;
CONTRÔLER LA PRESSION MAXI DE
RÉGLAGE.
LA REMPLACER;
BRANCHER LE CÂBLE DE
L'ÉLECTRODE DE DÉTECTION;
SI LA TENSION MESURÉE ENTRE
NEUTRE ET TERRE EST PAREILLE À
LA TENSION MESURÉE ENTRE PHASE
ET TERRE, IL FAUT INSTALLER UN KIT
DE TRANSFORMATION PHASE-PHASE
(REF. 88021LP).
VÉRIFIER LE BRANCHEMENT
ÉLECTRIQUE;
LA REMPLACER.
Gazania 3.25/25 - Version 1 du 21/06/2017
RÉARMEMENT
R É A R M E M E N T
MANUEL (APPUYER
SUR
LA
TOUCHE
RESET '
').
R É A R M E M E N T
MANUEL (APPUYER
SUR
LA
TOUCHE
RESET '
').
49