Honeywell Home T6 Pro Z-Wave Guide D'installation Professionnelle page 19

Thermostat programmable
Masquer les pouces Voir aussi pour T6 Pro Z-Wave:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

# ISU
ISU Name
ISU Options (defaults in bold)
1100
UV Devices
0 - 2
1105
UV Bulb 1 Reminder
Off, 6, 12, 24 months
Off, 6, 12, 24 months
1106
UV Bulb 2 Reminder
1401
Idle Brightness
0= Off, 0 - 5
1410
Clock Format
12 hour, 24 hour
1415
Daylight Saving
On, Off
0=Off, -3 °F to 3 °F (in 1 °F increments) or
1420
Temperature Offset
-1.5 °C to 1.5 °C (in 0.5 °C increments)
1425
Humidity Display
0=Off, -12% to 12% (in 1% increments)
Offset
Notes
Some systems may have two UV devices, one for the A-Coil and another for Air Treatment. A replacement
reminder can be setup for each one separately.
Adjust brightness of an inactive backlight (idle screen) from default 0 (backlight off) to 5 (maximum bright-
ness). Brightness level higher that 0 will be applied and enabled for user to change in user menu only if ther-
mostat is powered by 24 VAC (C-wire)
Set to Off in areas that do not follow Daylight Saving Time.
0 °F - No difference in displayed temperature and the actual room temperature. The thermostat can display up
to 3 °F (1.5 C) lower or higher than the actual measured temperature.
0% - No difference in displayed and actual room % relative humidity. The thermostat can display up to 12%
lower or higher than the actual measured % relative humidity.