Zip HydroTap ® G4 CS175

5. Using the Tap

EN
A
Cold water lever
Close the valve on the hose and touch 'Next'.
7. Using a 6 mm Allen key or a large flat blade screw driver to adjust the flow rate of
sparkling water to 1.6 l/min at the carbonation valve.
a. Rotate the adjustment screw "A" clockwise to decrease the flow.
b. Rotate the adjustment screw "A" anti-clockwise to increase the flow.
To measure the flow rate you have set, use a measuring cup or jug and run the spar-
kling water for 15 seconds. (The HydroTap has a default 15 seconds dispense time,
which will help in your flow rate set up.) Multiply the amount of water dispensed in
that 15 seconds by 4 to get your flow rate in litres per minute. 1.6 litres per minute is
the optimum flow rate.
Note: If you adjust the flow rate too high, you will empty the carbonation can of
water leaving only CO
Take care NOT to use excessive force during adjustment of the valve.
8. The unit will then be in normal operating mode.
9. Register the appliance with the customer service department online at
www.clage.com.
Note: If the drinking water system has not been used for several days, allow the
tap to run cold water for about five minutes.

Operation

Press the blue 'chilled' lever to dispense cold water. Pull the lever up to dispense cold
water continually. The water will flow for 5 to 15 seconds. This time can be set in the
Sparkling water lever
menu. The lever then has to be manually returned to the Off position.
Press the blue 'sparkling' lever to dispense sparkling water with carbon dioxide added.
Pull the lever up to dispense sparkling water continually. The water will flow for 5
to 15 seconds. This time can be set in the menu. The lever then has to be manually
returned to the Off position.
Blue light
• On all the time: temperature of chilled water is at the set temperature.
• Flashing: the water has not yet been chilled to the set temperature.
White filter LED
• Flashing: the filter needs to be replaced. This LED starts flashing according to filter
use and the filter capacity set in the menu.

Menu

The undersink unit has a touch screen which can be used to set and read the operating
parameters. The following settings can be carried out in the menu:
White filter LED
'Language'
Select the language used in the menu.
'Information'
Shows data specific to the unit and any errors occurring.
'Install'
The steps that are necessary when using the unit for the first time can be viewed again
for maintenance purposes.
Flush filter – place the end of the hose located at the filter in a collecting container and
open the isolating valve on the hose before starting to flush the filter.
Reset filter – resets the filter consumption data.
CO
flush – air and water inside the carbonizer are flushed out with carbon dioxide to
2
ensure that the carbonizer operates correctly. Wait about 10 seconds and then touch
to be dispensed from the tap.