A
Lock to be opened with supplied special key.
B1
The corner details can be lifted and are prepared with knock-
outs used for sealing or hiding cable entry. The position of
them should however remain (due to mechanical differences).
B2
They are numbered like this:
81284 (B1) = Lower left corner.
81285 (B2) = Upper left corner.
C
The box is fastened on the wall with four screws. Brackets are
supplied to allow for using glands M12x1.5 (these are not
included). If glands shall be used the default washers have to
be removed.
D
The cables can either be safely mounted (cable goes over the
edge) - or via knockouts in the same edge. Prepared with fixing
details for securing the cables with cable ties.
E
Power in: Terminal block nos. 1 and 2. 10-40V DC or 8-28V AC.
F
Opening relay. Voltage free contacts. Maximum load 2 A.
G
Relay for Warning, Monostable Alarm by-pass, Alert or Duress.
Software controlled. When Alert is selected also the tamper
switch will activate the relay.
H
RS485 connection for system communication Com A & Com B
to USB-RIF/2 (Entro Lite), next DC800 or SR34i (Entro).
I
Input for door monitor contact. Indicates open or closed door.
J
Remote opening input. For connection of an exit request but-
ton (push to make).
C
C
B2
B2
81285
81285
D
D
A
A
81284
81284
B1
B1
E
E
F
F
G
G
H
H
I
I
J
J
K
K
ENGLISH
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
A
A
0
0
B
B
P
P
R
R
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
A
A
0
0
B
B
Q
Q
K
Connection of card reader/keypad. Maximum load 300 mA.
Maximum distance for BCLINK readers are 100 m (dependant
on cabling). Maximum distance for Clock & Data readers, e.g.
proximity reader are 50 m.
L
Jumper for output voltage selection to reader/keypad +5V or
Vin= incoming supply.
Warning! Make sure the setting is correct, otherwise readers
will be damaged.
Default: +5V.
M
Jumper for interface selection - Clock & Data, BCLINK or
Wiegand (26bit, 32bit or 8bit PIN code).
Default: BCLINK.
N
Jumper for system configuration - Stand-Alone, Entro Lite or
Entro.
Default: Stand-Alone.
O
Jumper for address selection 1-8 for Entro Lite or Entro.
Default: Address 1.
P
Tamper switch. Gives warning if the DC800 controller's lid is
opened. Note! Will also activate the relay in item G when this
is setup as Alert.
Q
Keypad 0-9 plus A & B to programme the DC800.
R
LEDs (red, yellow & green) that together with the buzzer indi-
cates the different steps in the programming sequence. When
the DC800 is in idle mode, the green LED will flash approx.
every 5 second to indicate that the DC800 powered.
C
C
L
L
M
M
N
N
O
O