ECOPOINT USER MANUAL / MANUEL D'INSTRUCTIONS
-
Another safety timer will interrupt the charging process if the overall charging time exceeds 15 hours
-
If a power failure takes place during the charging process, all data concerning the current charging process
are stored. On power-fail restart the charging process is resumed from the point reached before
interruption.
-
If battery is disconnected during the charging process, the battery charger automatically stops the
charging process and signals a failure.
EQUALIZING CHARGE
If you are in ON :
Pressing the ON/OFF you switch OFF the charger
If you are in OFF
If you press ON/OFF less than 2,5 sec , WHEN you release the key you restart a new charge
If you press ON/OFF more than 2,5 sec , WHEN you release the key you restart a Equilizing charge
That is a short charge where the 5% of Ah is filled into the battery
-
If battery charger remains connected to battery when the charge is over, an automatic equalizing charge
will begin after 16 hours. The battery charger calculates battery capacity making use of the average
capacity calculated in the last 7 charging cycles duly completed.
-
During the equalizing charge the "FULL" green LED will blink.
-
If battery remains connected to charger for a long time, a floating cycle will be performed every 7 days in
the same way as equalizing is performed.
H)

LED's and DISPLAY INDICATIONS

-
All significant charging data are displayed on a backlit display: Cell Voltage, Charging Current, Restored
Capacity (Ah), Charging Time and Failure Messages, if any.
-
In addition three LED's indicate the charge state.
LED1 : INITIAL CHARGE
LED2: FINAL CHARGE
LED3 : END OF CHARGE /
EQUALIZING / FLOATING
H.1) LED's INDICATIONS
Power supply from mains only
Power supply from battery only (power failure)
Card lighting
Execution of automatic start with power on
Execution of automatic start with power off * > With power on
Initial charge
Final charge
Charge finished (without faults)
Charge finished (with faults)
Pause during equalizing or floating
Charge during equalizing or floating
Mains failure
Low Battery Voltage
High Battery Voltage
Timeout Initial Charge
Total Charge Safety Timer
Battery disconnection
Interruption by push-button ON/OFF
Indications
LED 1 red
OFF
BLK
3 FLASH
ROT.FLASH
BLK
OFF
BLK
OFF
OFF
ON
OFF
OFF
BLK
BLK
BLK
ON
ON
OFF
NO CHANGE
pag. 8
file: MU120037_MAN UT_ENERPOWER-PULSE_ECOTEC
Revisione n° 2 del 2015/01/14
LED 2 yellow
LED 3 green
OFF
OFF
BLK
BLK
3 FLASH
3 FLASH
ROT.FLASH
ROT.FLASH
BLK
BLK
BLK
BLK
OFF
OFF
BLK
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
BLK
BLK
BLK
BLK
BLK
BLK
BLK
OFF
ON
OFF
ON
OFF
OFF
NO CHANGE
NO CHANGE