Télécharger Imprimer la page

O&O BATT-US Manuel D'installation Et D'utilisation page 4

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EN
1. GENERAL FEATURES
This accessory completes the electronic equipment if you need to keep the no-parking device raised when there is a power failure,
powering the no-parking device's electric emergency brake directly. The battery charger card maintains the buffer battery in peak
effi ciency that will work whenever there is a power failure.
2. CONNECTIONS AND TECHNICAL SPECIFICATIONS
The use of this accessory is only for what is described above.
Other uses besides those mentioned by the manufacturer are forbidden.
Wire the accessory, using ducts and cable clamps that will maintain the container's original protection level.
To ensure correct operation the electronic BATT-US card must be connected to the same power line as the CDS control unit.
Lastly, with two leads having a cross section of at least 1,5 mm
BATT-US card to contacts BAT + and - (connector J10) on the CDS card respectively.
Wire the accessory, using ducts and cable clamps that will maintain the container's original protection level.
To ensure correct operation the electronic BATT-US card must be connected to the same power line as the CDK-US control unit.
Lastly, with two leads having a cross section of at least 1,5 mm
BATT-US card to contacts "13-14" on the CDK-US card respectively.
3. MAINTENANCE
We recommend having the no-parking device checked thoroughly every 6 months as well as the buffer battery that comes with
the accessory, BATT-US.
Measure the battery charger's output voltage by disconnecting the battery from the faston contacts and connecting a multimeter,
measuring in Volt DC. Voltage should be about 13.8V. If the output needs adjusting do it via trimmer VR1.
If you fi nd that the battery is no longer effi cient, take it to the appropriate disposal centres and replace it with one of the same
quality and that has exactly the same electrical features.
4. TECHNICAL DATA
Connections and maintenance
BATTERY CHARGER CARD
FOR CONNECTING TO THE CONTROL UNIT
2.1 CONTROL UNIT CDS
2.2 CONTROL UNIT CDK-US
Supply voltage:
Max power absorbed:
Battery:
Charging voltage:
Max. charging current:
Max. service in black-out: 10h (1 bollard), 5h (2 bollards),
Short circuit protection:
Protection level:
and no longer than 5 m, connect terminals V. OUT + and - of the
2
2
and no longer than 5 m, connect terminals V. OUT + and - of the
230V +/- 10%
12VA
12V 7Ah
13.8V
0.5A
4h (3 bollards), 3h (4 bollards)
Fuses are used
IP54
- 4 -

Publicité