Geberit 616.235.00.1 Instructions De Montage page 23

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
Commissioning
Prerequisites
The Geberit sanitary flush and malfunction
diagnosis are commissioned using a smartphone
and the Geberit SetApp. The Geberit SetApp is
available free of charge for Android and iOS smart-
phones in the respective app stores (see QR code).
The app communicates via a Bluetooth® interface
with the Geberit sanitary flush.
Commissioning with the Geberit
SetApp
Until the product is commissioned, the red LED on
the control unit of the Geberit sanitary flush flashes.
1
Install the Geberit SetApp on your
smartphone. To install the app, scan the QR
code or visit app.geberit.com/setapp.
2
Start the Geberit SetApp and perform the
following steps for commissioning.
3
Establish a connection with the Geberit
sanitary flush.
4
Launch the <Basic settings> menu. Check
the settings and make any necessary
changes.
5
Call up the <Flush settings> menu. Program
the flushing parameters.
If the Geberit sanitary flush is linked to the
building service management system via the
RS485 or digital I/O interfaces, it is not
necessary to program the flushing
parameters. The sanitary flush will be fully
controlled by the building service
management system.
9007206989937291-1 © 12-2020
970.145.00.0(01)
Factory settings
If no flushing parameters are programmed, the
Geberit sanitary flush will function using the
following factory settings:
Table 1:
Factory settings
Parameter
Description
Flush interval Time between 2 flushes
Flush time
Duration of each flush
However, we recommend that the flushing
parameters always be programmed.
Display of operating state
The control unit of the Geberit sanitary flush
displays the following operating states:
Table 2:
Operating states
Element
Status
Short flash
pulse
Long flash
Green LED
pulse
On
Off
On
Red LED
Flashing
Off
2)
On
1)
Buzzer
Off
<Test>
Press button
button
1)
The buzzer is activated at the factory. If desired,
deactivate in the <Basic settings> menu.
2)
The buzzer can be suppressed by pressing the
<Test> button. If the malfunction continues for longer
than 24 hours, the buzzer will automatically
reactivate.
Value
72 h
180 s
Meaning
Normal operation,
operating voltage on
Normal operation,
Bluetooth® interface
active
Solenoid valve open
Operating voltage off
Malfunction, diagnose
with Geberit SetApp
Warning, diagnose
with Geberit SetApp
Normal operation
Malfunction, diagnose
with Geberit SetApp
Normal operation or
buzzer deactivated
Test solenoid valves.
If Bluetooth®
interface is active:
disconnect
connection.
In the event of an
active malfunction:
suppress buzzer.
23
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

616.236.00.1

Table des Matières