Novellini NEW HOLIDAY A80 Notice D'installation, Utilisation Et Entretien page 57

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 4
PRODUCT GUARANTEE:
All products purchased by consumers, as defined in Article 3 of
the Consumer Code (Legislative Decree no. 206 of 6 September
2005 and subsequent amendments), are covered by the legal
guarantee of the seller under Article 128 and subsequent
amendments of the consumer Code. In case of lack of conformity
of the product, we invite the consumer to contact their dealer
within the statutory deadline.
WATER TREATMENT
• The hardness of the domestic water supply affects the operation
and the cleaning frequency of the thermostatic mixer and boiler
unit.
• In case of water with hardness above 15°f an antiscale device is
recommended. The choice of device should be made according
to the characteristics of the water supply.
This symbol indicates important product instructions
or important safety information.
IMPORTANT:
Before you start to assemble and install the product, carefully
read through all the instructions. Unpack the components and
check that nothing is missing and that there are no damaged
or faulty components, remove the transparent protective film.
Before you install the shower cubicle in its final position, perform
a test run. Run the unit for several minutes and check for water
leaks and any damage caused during transport and handling.
This product should be installed by suitably skilled personnel.
N.B.: This product is designed for installation on finished walls
and floors.
Warranty claims must be produced with the purchase invoice and
the product assembling instructions.
The drawings and illustrations in this manual are provided for
information purposes only.
The manufacturer reserves the right to make changes and
improvements without prior notice.
Electrical connection:
Novellini S.p.a. hereby certifies that the product conforms to
current health and safety regulations at the time of sale and
that the product has the CE-mark and Declaration of Conformity.
All products and components are tested during manufacture in
accordance with the relevant reference standards and company
quality system procedures. In order to ensure that your Novellini
product maintains these high standards after installation and
throughout its service life, please read the following instructions.
1) Check that the mains electrical equipment connected
to cubicle conforms to current electrical standards and
regulations and is fitted with a fully efficient earth connection.
2) Current electrical regulations forbid the installation of any
electrical equipment (e.g. plugs, switches) inside a radius of
60 cm from the cubicle and at a height of 225 cm.
3) Check that rating of the mains power supply line matches
the absorbed power specified for the cubicle (see Technical
specifications).
4) The electrical connection between the cubicle and the mains
must be protected against water spray and must have a
protection rating of IP55 or higher.
5) The electrical equipment upstream from the cubicle must
be fitted with an omnipolare 30 mA switched circuit breaker
with a minimum contact opening of 3 mm, which conforms to
current electrical regulations.
6) Novellini S.p.a. declines all responsibility for injury or damage
resulting from failure to observe these instructions.
1
~
Dismantling the shower valves:
In the event of the formation of lime scale and a resulting
malfunctioning of the shower valves, dismantle the parts (fig.
A/B/C...). We recommend you immerse the cartridge in normal
vinegar until it is completely lime scale-free.
To ensure correct operation of the thermostatic mixer, the unit
must be supplied from a boiler or a water heater providing 6 to 7
litres per minute of water at a temperature of 60/65°C.
INSTRUCTIONS FOR USE:
electrocution Hazard. Do not use electrical equipment of
any type inside the shower enclosure when the shower
is operating.
Massage functions:
CASCADE.
FIXED SHOWER HEAD.
HYDRO-NECK.
HYDRO-BODY: for a total body massage concentrating on the
spinal column. Relieves back pain, tiredness and muscular aches.
Ideal for reducing physical stress.
PRECAUTIONS:
Integrated cubicles will provide a variety of benefits if used
properly. You should observe the following precautions.
1) Do not exceed a maximum water temperature of 45°C.
2) Do not use the shower or the steam bath after a heavy meal
and while you are still digesting.
3) Do not exceed the maximum load of the seat (120 kg).
4) Children and the infirm should only use the cubicle under the
supervision of an adult.
5) Do not use the steam bath for longer than 20 to 30 minutes.
Maximum permitted steam bath times vary with age and
body weight.
6) Persons with serious heart problems, high blood pressure and
acute illnesses should consult a medical practitioner before
using the steam bath.
7) SCALDING HAZARD. During a steam bath, keep your feet away
from the steam outlet nozzle.
CLEANING THE SHOWER UNIT:
CARING FOR YOUR CUBICLE
The cubicle panels are made with acrylic parts and must be
cleaned using a liquid detergent and a soft cloth or sponge.
Use a good quality household liquid detergent. To prevent scale
deposits, wipe dry using a chammy leather or a soft lint-free
cloth that removes stubborn deposits without leaving traces.
Limescale deposits may be removed using specific detergent
products. To restore shine to the acrylic surface polish with an
ordinary wax polish such as car wax.
DO NOT USE ABRASIVE CLEANERS, ALCOHOL OR ALCOHOL BASED
PRODUCTS, ACETONE OR OTHER SOLVENTS.
-57-
TROUBLESHOOTING:
600 mm
Before calling the Service Centre, check that:
2400 mm
• The hoses are properly connected and not kinked.
2
• Hot and cold water is being correctly delivered to the wall
3
fittings.
(I)
• The water supply system was bled before the shower unit was
installed.
• The mains power supply is reaching the steam generator and
the green Power On LED on the control panel is lit.
WASTE DISPOSAL:
For the disposal of the product or its parts, follow the local
regulations on matters of waste disposal. For Italy, Legislative
Decree n. 152 of April 3, 2006 will hold, and for the other EU
countries, Directive 2008/98/EC.
ENGLISH
Romanore di Borgo Virgilio, lì 01.01.2014
Novellini S.p.a.
Marco Novellini
Amministratore delegato

Publicité

Table des Matières
loading

Table des Matières