Télécharger Imprimer la page

golmar VESTA GB2 Guide Rapide page 4

Publicité

Les langues disponibles

Les langues disponibles

VESTA2 G 2 MONITOR
B
SAFETY PRECAUTIONS
- Always disconnect the power supply before installing or making modifications to the device.
and handling of these devices must be carried out by authorised personnel.
-
The
installation
- The wiring must run at least 40 cm away from any other wiring
- Do not overtighten the screws on the terminal block.
- I
nstall the monitor in a dry
and
protected
place without
- Do not place in humid, dusty or smoky locations, or near sources of heat.
- Before connecting the system to the mains, check the connections between the door panel,
power supply, distributors and monitors.
- Always follow the instructions contained in this manual.
( )
CHARACTERISTICS
*
- Hands-free monitor.
- 4.3" TFT colour screen.
- Monitor with simple installation (non-polarised 2 wire BUS).
- Capacitive buttons to access and select menu functions.
-
User menu
.
- Installer setup.
- Screen and volume settings menu.
- Start/stop communication button.
- Door release push button.
-
Status LEDs
.
- Dip switches for setting the monitor address (call code).
SYSTEM OPERATION
- To make a call, the visitor must press the button of the apartment; an audible sound indicates that
the call is being made and LED
will turn on. If vocal synthesis is activated then a "call
progress" message will indicate a call is being made. At this moment the apartment's monitor(s)
receives the call. During the call the visitor can correct his call by pressing a push button
corresponding to a different apartment, in which case the original call is cancelled.
- The ring tone lasts for 40 seconds. Without alerting the visitor, their image appears on the master
monitor
to receive the call For
.
kit
Villa
application
"apartment 1" or monitor with code 16 if the call is in "apartment 2") when receiving the call
without the visitor being alerted.
If the call is not answered within 40 seconds, LED
- To establish communication, press button
will turn on. If the vocal synthesis is enabled the message "you can speak now" will be heard
confirming the communication is activated.
- Communication will last for one and a half minutes or until button
communication has finished, LEDs
and
synthesis is activated, a "Communication is finished" message will indicate that the call is over.
- To open the door, press button
during the call or communication processes: one press will
activate the lock release for five seconds and LED
synthesis is activated, a "Door
is o
pen" message will be indicated on the door panel.
- The descriptions of the function push buttons are found on page 3.
( ) For more information, see the "TVESTA2 GB2 User Manual (code 50121908)".
*
https://doc.golmar.es/search/manual/50121908
.
risk of drip or water
projections
.
: the image appears on the monitor (with code 0
will turn off and the channel will be freed.
on any monitor in the apartment. Door panel LED
is pressed again. When
will turn off and the channel will be freed. If vocal
will also turn on for five seconds. If vocal
2
VESTA2 G 2 MONITOR
B
MONITOR DESCRIPTION
( )
*
a.
Microphone
.
b. 4.3" TFT colour screen.
c. Close push button.
d. Menu push buttons.
e. "Do not disturb" push button/indicator.
f. Start/stop communication
During standby: Display door panel image.
Menu push buttons and status LEDs:
Menu access and function selection push button.
Menu scroll down push button.
Menu scroll up push button.
Menu back push button.
( )
*
Monitor address (code) setup:
1-apartment kit
2-apartment kit
is
in
APARTMENT 1
APARTMENT 1
VESTA2
VESTA2
CODE 0
CODE 0
( )
2-apartment kit: Monitor code 16 is the last,
s
1
dip 6 of the end of line to ON.
MONITOR INSTALLATION
( )
*
Location
1.60m
( ) For more information, see the "TVESTA2 GB2 User Manual (code 50121908)".
*
https://doc.golmar.es/search/manual/50121908
a
h
b
i
c
j
d
k
e
l
f
g
g.
Door
release
During standby: Press for 10 seconds to
activate/deactivate the "doctor mode" function
(function code [9018] must be activated).
h. Attachment holes.
function push button
.
i. Horizontal cable input.
j. Con ector.
n
k. BUS connection terminals.
l. Configuration DIP switch.
Power supply
Push button: End call/communication.
During standby: Enter/exit menu mode.
"Do not disturb" function access push button.
LED on: "do not disturb" mode activated.
LED blinking: "doctor mode" activated.
LED off: function not activated.
Building
s
Dip6: Sets the end of line. Set to ON in monitors where the video cable
APARTMENT 2
terminates. Remainder set to OFF.
VESTA2
Dip1
to
Dip5:
Set the monitor address (addresses 0 to 31)
Switches set to OFF have a value of zero.
The values of the switches set to ON are shown in the enclosed chart.
The monitor code will be the sum of the values of the switches set to ON.
( )
1
CODE 16
Value chart
Switch number : 1
2
3
4
ON
value
:
1
2
4
8 16
Surface
Embedding box
4 30
x
3
function push button.
status LED
.
.
ON
DIP
5
1
2
3
4
5
6
E
xample
: 0 + 0+4+0+16 = 20
Screws supplied with the
embedding box.

Publicité

loading