Installation
Menu 3 + Menu 4:
Setting the end positions
1. Keep the programming button (PROG button) (D) pressed in for
approximately 3 seconds. The display shows "3".
2. Press the OPEN button (B) and check if the garage door moves to the
OPEN position.
3. If the garage door moves in the wrong direction, keep the programming
button (PROG button) (D) pressed in for approximately 5 seconds until a
chaser light appears.
4. Keep the OPEN button pressed until the garage door is at the desired
end position OPEN. If needed, press the CLOSE button (C) to adjust the
position.
5. Once the garage door is at the desired OPEN position, press the
programming button (PROG button) (D). The display shows "4".
6. Press the CLOSE button (C) as soon as the display flashes.
7. Keep the CLOSE button pressed until the garage door is at the desired
end position CLOSE. If needed, press the OPEN button (A) to adjust the
position.
8. Once the garage door is at the desired end position CLOSE, press the
programming button (PROG button) (D). The display shows "0".
9. Continue with the force learning cycle.
Force learning cycle
Warning:
During this procedure, the operator automatically learns the normal mechanical force required to
open and close the garage door. Force limits are deactivated until the conclusion of the learning
cycle. Keep a sufficient distance from the entire path of motion of the garage door!
Do not interrupt this procedure.
Note:
During this procedure the display shows a "0".
1. Press the OPEN button (B) or use the set hand transmitter. The garage
door moves from the end position CLOSE and moves to the end position
OPEN.
2. Press the OPEN button (B) again or use the set hand transmitter. The
garage door moves from the end position OPEN to the end position
CLOSE.
After about 2 seconds, the '0' on the display goes out.
Note: After completing the force learning cycle, the display '0' must go out.