Technical Specifications - Aube Technologies TI035 Mode D'installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Programming the Schedule
The switch can hold up to 2 programs which are repeated every day. When you place the
timer in Automatic mode, it will activate the load at the start of each program and deactivate
it at the end of the program. You need to set the following parameters:
P1 ON
P1 OFF
Press the PGM button until the desired parameter is displayed.
1)
If you have entered your city's parameters (see section 7), the parameters P1 ON and
P2 OFF show the sunset time and sunrise time for this time of the year. If the timer is
used for lighting, when placed in AUTO mode, it will turn the light ON at sunset and will
turn it Off at sunrise. For example:
2)
Press the HOUR and MIN buttons to set the time.
Example: If you want your lights to turn On at sunset and to turn Off at 10:00 PM, set
P1 OFF to 22:00. If you also want your lights to turn back On at 5:00 AM then turn Off
at sunrise, set P2 ON to 5:00.
P1 ON
P1 OFF
NOTE: P1 OFF and P2 OFF have priority over P1 ON and P2 ON respectively. For
example, if sunrise is at 4:58 and P2 ON is set to 5:00, the lights will not turn on.
You can replace the sunrise and sunset times by fixed times. Select program P1 ON or
P2 OFF and enter the desired time using the HOUR and MIN buttons.
3)
Press one of the control buttons or close the switch door to return to normal operation.
Clearing a programmed time
Press the PGM button as many times as needed to display the programmed time.
1)
Press the CODE button. The time will be erased and - : - - will be displayed.
2)
NOTE: For P1 ON and P2 OFF, if you have programmed the city parameters, the
programmed time will be replaced by sunset time and sunrise time respectively.
3)
Press one of the control buttons or close the switch door to return to normal operation.

Technical Specifications

Supply: 120 VAC, 50 / 60 Hz
Maximum load: 2400 watts resistive or inductive, 1 HP motor
Operating temperature range: 5°F to 122°F (-15°C to 50°C)
Storage temperature range: -4°F to 122°F (-20°C to 50°C)
Power outage: The programs are protected by a rechargeable battery. The screen is blank
during the power outage.
Solar table precision: +/- 11 min. (max error around poles)
:
Start time of program 1
:
End time of program 1
P1 ON
:
20:38 (sunset)
P1 OFF
:
--:-- (blank)
:
20:38 (sunset)
:
22:00 (programmed)
P2 ON
:
Start time of program 2
P2 OFF
:
End time of program 2
P2 ON
:
--:-- (blank)
P2 OFF
:
6:10 (sunrise)
P2 ON
:
5:00 (programmed)
P2 OFF
:
6:10 (sunrise)
4/6