6. Using diagonal wire cutting pliers, gently snip out the
rectangular damper vent covers at the perforations.
A
A. Diagonal wire cutting pliers
B. Rectangular damper vent cover
7. Hold the blower motor wire, put the wire through the blower
motor bridge.
A. Blower motor bridge
B. Blower motor wire
8. Lower blower motor back into the microwave oven. Exhaust
ports face the back of the microwave oven.
A. Exhaust Port
9. Reconnect the blower motor wire into the connector.
A. Blower motor wire
B. Connector
6
B
A
A
B
10. Reattach the 2 blower screws into the recessed holes in the
back of the microwave.
A
11. Check to make sure the 2 screws are secured properly in the
A
blower motor screw holes, so that the motor cannot move.
B
A
A. Screws
B. Blower motor screw holes
12. Return the damper plate to its original horizontal position.
A
B
A. Screws
B. Recessed holes
B
A. Damper plate