Danfoss ECiceguard 18 Readymade Manuel D'installation page 9

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Instruction
Regulation
As self-limiting heating cables always draw
current regardless of the temperature Danfoss rec-
ommend a thermostat that disconnects the cable
in periods where heating is unnecessary in order to
save energy.
The optimal control of Danfoss self-limiting
heating cables is achieved by using ECtemp
electronic thermostats. ECtemp thermostats give
a quick and effective regulating and take both
comfort and economy into consideration.
Thermostats
Type
Mounting
ECtemp 610
Outdoor IP 44
ECtemp 330
DIN rail
ECtemp 316
DIN rail
ECtemp 850
DIN rail
ECtemp 316 Frost protection of roofs gutters and down pipes.
ECtemp 330 Frost protection of pipes/hot-water supply, ground.
ECtemp 610 Frost protection of pipes.
ECtemp 850 Frost protection of roofs gutters and down pipes, ground.
Sensors and other accessories
Wire sensors 2,5 m, 6,0 m and 10,0 m
(ECtemp 330, 316, 610)
Wire sensor for roofgutter (ECtemp 850)
Moist sensor for roofgutter (ECtemp 850)
Aluminium tape, 38 mm x 50 m rolls with
'WARNING' text
Connection kit to terminal box, including
cable terminal
Connection kit to cold tail, including cable
teminal
Fitting set for two heating cables
Cable glands
088L8004 / VIMSB102
ECiceguard 18 Readymade
to choose from according to the demands of the
individual installation.
Min. temp.
Temp. range
adjustment
-10° - +50°C
-10° - +10°C
+5° - +45°C
-10° - +50°C
-10° - +5°C
-10° - +40°C
There is a wide variety of ECtemp thermostats
Hysteresis
Sensor
0,4°C
0,4°C
0,4°C
0,2° - 6°C
Moisture +
-
temperature
Spaceclips
DEVIclip Guardhook™
DEVIclip Roofhook™
DEVIclip Gutterrelief™
Colour
Wire
Polar-white
Wire
Grey
Wire
Wire
Grey
Grey
© Danfoss | FEC | 2019.04 | 9
GB

Publicité

Table des Matières
loading