Installation Instruction
ECiceguard 18 cable specifications
Application
Colour
Dimensions
Sheath
Voltage
Effect
Capacitive leak current
Min. installation temperature
Min. start-up temperature
Max. temperature ON / OFF
Length of cold-lead
• The effect stated is measured with the Iceguard heating cable installed on an insulated metal pipe.
• When self-limiting cables are installed in the open, the effect may be reduced by approx. 50%.
• When planning the installation it must be considered that self-limiting cables may reduce the opera-
tional effect over several years.
ECiceguard 18 heating power output of heating cable installed and meagured on pipe
W/m
40
35
30
25
20
19
18
17
16
15
10
5
0
0
088L8004 / VIMSB102
ECiceguard 18 Readymade
10
20
Roof / gutters / downpipes
Black
11,3 x 5,8 mm
Black TPE, UV
230 V
18 W/m at 10°C (approx. 36 W/m in ice)
30 mA/km cable
-50°C
-40°C
65 / 85 °C
5 m, 2 x 1,5 mm
2
, screened
ECiceguard 18
30
40
50
60
Pipe temperature (°C)
© Danfoss | FEC | 2019.04 | 5