SAFETY AND RESPONSIBILITY

-
Follow the instructions in this manual when installing, operating, and maintaining
the MixRite pump and take additional safety measures appropriate to the liquid
being pumped and the temperature of the water.
-
During any action, the operator must stay in front of the MixRite and wear
protective eyewear, clothing and gloves and use proper tools. DO NOT USE
METALLIC TOOLS.
-
It is the responsibility of the owner/operator to make sure water flow and
pressure do not exceed the MixRite specifications.
-
An air inlet, impurity or chemical damage to a seal can interrupt the dosing
function. It is recommended to periodically check that the solution is being
correctly drawn up into the MixRite.
-
Be extremely careful in the presence of hazardous substances (e.g. corrosives,
toxins, solvents, acids, caustic, flammables, etc.).
-
Before applying any aggressive chemicals, please consult your distributor to
confirm compatibility with the dosing pump.
-
The user must respect the recommendations given by the manufacturer of the
chemical product.
-
Change the suction tube as soon as it seems damaged by the chemical.
-
It is advised to relieve the pressure after use.
2.

TECHNICAL DATA

2.1. MixRite Operational Conditions

Minimum Flow Rate
Maximum Flow Rate
Minimum Temperature
Maximum Temperature
Operation Pressure Range
*7 L/H (1.85 Gal/H) in P0 model only.
10 L/H (2.64 Gal/H)*
2,500 L/H (660 Gal/H)
4°C (39°F)
40°C (104°F)
0.2 Bar to 8 Bar (2.9 to 120 PSI)