O&O CSB-BR Manuel D'installation Et D'utilisation page 22

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Par
Function

Output 4

Exiting the menu/saving
Description of level 2 parameters

·
: Request for maintenance
- : the request for maintenance is not active.
- : at the end of the countdown, by means of counters  and , one of the programmed outputs is activated (see parameter
,,)
- : at the end of the countdown, by means of counters  and , one of the programmed outputs is activated (see parameter
,,) and the bar lights fl ash twice.


·
and
: Programming maintenance cycles in thousands and millions
Thanks to the combination of the two parameters the countdown can be set after which a request for maintenance is signalled.
Thousands can be set with the  parameter, millions with the  parameter.
Example: to set 275,000 maintenance manoeuvres set  on 0.2 and  on 75.
The value displayed in the parameters updates along with the manoeuvres.
· Arm locking device confi guration:
To use the arm locking device, connect the enabling contact to OUT2 or OUT3 or OUT4 and set the corresponding parameter
, or  to .
The following table gives the 3rd level functions and the single parameters.
= DEFAULT value set in factory.
Par
Function

Advanced setup

PDM dynamic input polarity

Output 2 polarity

Output 3 polarity

Output 4 polarity

Opening speed (%)

Closing speed (%)

Speed selection input

Exiting the menu/saving
: request for maintenance
: photocell triggering
: reverser triggering

: PDM contact actuated
: arm closed
: arm open
: stop contact actuated
: warning fl ash
: Arm locking device
Exit programming and view machine Statuses (see notes  automa-
tion Statuses display after the 1st level table)
3ND
6.4
LEVEL PROGRAMMING
: no advanced setup
: input open at on state (reserved)
: input N.O.
: input N.C.
: N.O.
: N.C.
: N.O.
: N.C.
: N.O.
: N.C.
 - 
 - 
: Disabled
: Enabled
Exit programming and view machine statuses (see notes  St auto-
mation statuses display after the 1st level table)
Available functions only for CSB-SP/XT
- 22 -
Settable data
= parameter value set during installation: must be indicated if
DEFAULT value is modifi ed.
Settable data









Publicité

Table des Matières
loading

Produits Connexes pour O&O CSB-BR

Ce manuel est également adapté pour:

Csb-spCsb-xt

Table des Matières