Charger Operation - Liberty Pumps 441 Manuel D'installation

Masquer les pouces Voir aussi pour 441:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Cha r ger Opera ti on
The charger circuitry opens under severe overload. This condition
may occur if attempting to charge any severely discharged or
heavily sulfated battery. Once opened, the charger stops charging
for a short period and then automatically resumes charging. The
AMBER LED (Charging) will be OFF until charging resumes.
Overloading could be due to an external load; remove the load
condition prior to attempting to recharge the battery.
The charger has reverse battery and short circuit protection. If a
reverse battery condition exists, unplug charger from AC power
and reverse the connections.
The unit will automatically detect the battery internal cells
condition as well as battery sulfated conditions.
The charger has internal overheat protection. The charger will turn
off power until the temperature is down to a safe level, then
automatically start charging again. All LEDs will be off.
The charger is designed to charge 12 V lead acid batteries.
Never charge lithium ion batteries on this charger.
The charge time is dependent on the Ah rating of the
individual battery. See chart below.
100%
75%
50%
25%
0%
11.5 V
11.9 V
VOLTAGE
*Approximate charge time using a constant current charger at
standard amps as specified on the battery. Charging times may
vary depending on the Ah rating of the battery.
4414000D
*Approximate
charge time
3–6 hours
5–11 hours
13–20 hours
12.3 V
12.7 V
13 V
Copyright © Liberty Pumps, Inc. 2019 All rights reserved.
Charger Details
Specifications
Input Voltage
Input Frequency
Output
Size without Cable
L x W x H
Weight
Approvals
Environmental Characteristics
Operating Temperature
Storage Temperature
Operating Humidity Range
Cooling
Charger Stages
Stages
Explanation
Gently charges the battery using a
Soft Start
reduced charge output until the
Change
battery voltages reaches 11.0 V.
Charges using a constant maximum
Bulk
current (1 A) until the battery
Charge
reaches 14.4 V.
Uses a constant voltage while
reducing the charging output
Absorption
current to ensure the battery
Charge
receives a full charge without
overcharging the battery.
Battery is fully charged and is being
Full/Float
maintained.
110–120 VAC
50/60 Hz
1 A @ 12 VDC
3.9 x 2.7 x 1.4 in
[105 x 68 x 35 mm]
0.9 lbs [0.4 Kg]
UL/cUL/FCC/BC/DOE
0 to 113°F [0 to 45°C]
-13 to 185°F [-25 to 85°C]
0 to 90% RH
Passive/Natural
LED
Indication
Amber
flashing
Amber
Amber
Green
– 13 –