The door release switch contacts are very versatile and can be
used with many AC/DC door or switch contacts. Be sure to use the
wire and power supply or transformer specified by the door or gate
release product being used.
paNic iNterface WitH security system
Run a line of 18 gauge solid copper, twisted pair approved low
voltage cable from the NWH300 or NWH300C rough-in location
to the security control panel. Setup the security panel to receive a
normally open dry contact for panic operation. (Refer to programming
procedures accompanying the security panel). Label and secure
cables at the NWH300 or NWH300C rough-in. Have a certified
security installer hook the NM100 up to the alarm system.
testiNg
After all connections have been made, insert the NM100 power plug
into NA300TA transformer and secure the master to the rough-in
using the 2 screws provided. If using the NF200CWH, NF100CWH
or NF100MWH frame with a NC300 player, install the master unit
over the frame. Do not over tighten the screws as the plastic may
distort or crack. Install the speaker panel on the master as shown.
Please be careful to only apply pressure on the speaker panel at
the corners and not in the middle. Check all functions by following
the guidelines in the Owners Manual shipped with the master unit.
If any difficulties are encountered, recheck all connections. If after
reviewing these instructions you are unable to resolve any problems,
contact technical support at 1-888-336-6151.
appeNdix a - NutoNe
systems
*Refer to frames below:
• NF100MWH – Replacing a master only system with an NM100
master
• NF100CWH – Replacing a combination system with an NM100
master and NC300 CD player
• NF200CWH – Replacing a master only system with an NM100
master and NC300 CD player (requires hole in wall to be made
larger)
• NF300RWH – Used on all indoor remote station replacements
• NF300PWH – Used on all outdoor or high sun area flush mount
remote station replacements
• NRKS200PWH – Used on all outdoor surface mount remote
station replacements
• NF300DWH – Used on older NuTone door station replacements,
not required for M&S replacements