Télécharger Imprimer la page

NuTone NM100 Serie Manuel D'installation page 4

Publicité

Les langues disponibles

Les langues disponibles

For the NWH300C Master Station and CD combination rough-in,
have a qualified electrician loop a power wire from the NA200TA
transformer enclosure to the NA300TA transformer enclosure
following the same procedure described previously and shown in
the next figure.
replaciNg tHe room statioNs
The remote and door stations use the existing wire and station
rough-in mounting frames or boxes. To replace the station, first
remove the old station. Leave the existing remote or door station
rough-ins in place.
After removing the remote station verify the integrity of the wire run.
Then install the mounting plate from the NF300RWH frame. Align
the plate on the wall either vertically or horizontally so that the screw
holes line up with those on the rough-in or box. Use a level to make
sure the plate is level. There are several screw hole locations on the
mounting plate so it can attach to many rough-in designs. Mount the
plate to the wall using the screws provided.
Next connect the wires to the retrofit remote station. Match the wire
colors to the corresponding screw locations on the NRS103WH
or NRS104WH remote stations. Please make sure to use only
NRS103WH remote stations in a 3-wire installation and NRS104WH
remote stations in a 4-wire installation. All 6-wire installations use
the NRS200WH remote stations. Please refer to appendix A for a
diagram of which NuTone and M&S systems map to the 3, 4 or 6-
wire (requires NM200 master) configurations. Refer to the following
two charts for the NM100 wiring diagram:
Three-wire Installations
Nm100
NutoNe
coNNectioN
iWa3 cable
Black
Blue Stripe or
Outside Copper Wire
Red
Center Wire
Green
Red Stripe or Outside
Silver Wire
Four-wire Installations
NM100
NUTONE 4
CONNECTION
CONDUCTOR
WITH GRAY
JACKET
White
Blue Stripe
Wire
Black
Gray/Copper
Wire
Red
Gray/Silver
Wire
Green
Red Stripe
Wire
NM100
M&S MS4XSC
CONNECTION
CABLE
White
White
Black
Black
Red
Red
Green
Green
Connect the remote station to the existing wiring using the diagrams
above. Place the remote station through the NF300RWH plastic
mounting frame. Position the frame either vertically or horizontally
depending on the remote station replaced. Place the remote station
into the rough-in ring and align the frame with the remote station.
100
model Nm
WH
Page 
Wire fuNctioN
Intercom Mic
Audio Input & Control
Ground
Speaker
Output/Monitor
Mic Input
M&S 4
WIRE
CONDUCTOR
FUNCTION
CABLE
WITH GRAY
JACKET
Silver Outside
Intercom Mic
Gray Wire
Audio Input
Next Copper
Intercom
Outside Gray
Control
Wire
Next Copper
Ground
Outside Gray
Wire
Outside
Speaker
Copper
Output/Monitor
Outside Red
Mic Input
Stripe Wire
NUTONE
WIRE
NW4S CABLE
FUNCTION
Red
Intercom Mic
Audio Input
Black
Intercom
Control
Orange
Ground
Yellow
Speaker
Output/Monitor
Mic Input

Publicité