Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23

8) TROUBLESHOOTING

No. Fault
Plunger discs cannot
1
enter the cartridge
Cartridge cannot be
2
removed from dispenser
Dispensing is interrupted
3
Unable to discharge
4
material
Leaking air noise
5
Uneven dispensing speed
6
Instruction handbook DP2X
Version 1.0 · 8.10.19
Cause
• Cartridge not fully inserted in
cartridge holder
• Foreign matter in cartridge guide
• Wrong diameter of plunger discs
installed
• Plunger discs are still in position
inside the cartridge
• Compressed air supply has been
interrupted
• Material has cured in the mixer
• Pressure not high enough
• Inlet pressure too high –
safety valve blowing off
• Leakage at compressed air
connection
• Leakage from handle
• Foreign matter in driving unit /
damaged sealing
7 of 10
Remedy
• Check that the correct cartridge
holder is installed and is not
damaged. Push cartridge fully down
into the cartridge sleeve.
• Remove foreign matter from
cartridge guide (do not use sharp
tools).
• Check the correct diameter of
plunger discs. Change plunger
discs if necessary.
• Fully retract the plungers by using
the retract button (check dispense
volume indicator).
• Check compressed air supply
pressure. Check connection to
dispenser.
• Replace the mixer. Refer to mixer-
open-time in technical data sheet of
materials to be dispensed.
• Gradually increase the pressure by
turning the pressure regulation
valve.
• Check and reduce inlet pressure to
adequate level.
• Check and tighten the adapter.
• If the source of air leakage is inside
the handle please send the device
to the manufacturer or authorized
service station for inspection.
• Send device to manufacturer
or authorized service station for
inspection (never use solvents to
clean the air path).
EN

Publicité

Table des Matières
loading

Produits Connexes pour Sulzer Mixpac DP2X 200

Ce manuel est également adapté pour:

Mixpac dp2x 400

Table des Matières