Maintenance And Repair; Notices; Technical Data - Sulzer Mixpac DP2X 200 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23

9) MAINTENANCE AND REPAIR

Notices

All maintenance and repair may only be
carried out by sites authorized by the manu-
facturer and exclusively by qualified and suit-
ably trained personnel (refer to the address
list at the back).
WARNING Risk of injury due to acci-
dental actuation of the dispenser and/
or flying device components!

Always disconnect the compressed air supply from
the dispenser during maintenance.
CAUTION Risk of injury from incor-
rect maintenance and repair!

The pneumatic drive unit (refer to item
4 in figure {A} on page II) may never be opened. If it is
necessary to service or repair the pneumatic driving
unit, please contact an authorized Sulzer-Mixpac ser-
vice center (refer to the list of addresses at the back).
NOTICE
Risk of damage due to incorrect
maintenance and cleaning!

Always keep the dispenser clean.

Never use any corrosive cleaning agents for clean-
ing the surface of the device (do not use products con-
taining silicone).
EN

10) TECHNICAL DATA

Operating pressure
Compressed air supply
Compressed air quality
Sound level
Recommended operat-
ing temperature
Relative air humidity
Transport and
storage temperature
Pressure adjustment
Weight
.
8 of 10
680 kPa (6.8 bar) (98 psi) max.
1000 kPa (10 bar) 145 PSI
ISO 8573-1:2010 [2:4:2]
83 dB
+5°C to +40°C
30% to 80% RH
(non-condensing)
0°C to +40°C
infinitely variable
DP2X-200: 1.7 kg
DP2X-400: 2.5 kg
Instruction handbook DP2X
Version 1.2 · 8.10.19

Publicité

Table des Matières
loading

Produits Connexes pour Sulzer Mixpac DP2X 200

Ce manuel est également adapté pour:

Mixpac dp2x 400

Table des Matières