7) OPERATION

Inserting the cartridge

Refer to figure {B} on page II:
CAUTION Risk of crushing by extend-
ing plunger!
1. Always push the cartridge with different volume
ratios with the higher volume (A-side) upwards into
the guides (1) and press downwards until it locks
into place.
Connect the dispenser to the compressed
air supply
NOTICE
Risk of damage due to incorrect com-
pressed air supply!

Observe the maximum supply pressure of the com-
pressed air supply. Refer to Chapter "10) Technical
data" on page 8.
1. Connect the compressed air hose onto the
compressed air inlet with the quick-release
coupling.

Leveling the cartridge pistons

Refer to figures {D} and {E} on page II:
1. Remove the retaining nut (11) and nose plug by
turning it by 120° counter-clockwise.
2. Set the pressure regulation valve (8) to the minimum
discharge quantity.
3. Press the trigger (7) until both components are
evenly pressed out of the cartridge.

Fitting the mixer

Refer to figure {F} on page II:
1. Fit the mixer (a) and secure in place by using the
retaining nut on the cartridge outlet (b).
EN

Dispensing the material

Refer to figures {G} and {H} on page II:
1. Press the trigger (7). Dispensing starts and the red
dispense volume indicator (3) moves forward.
When the trigger (7) is released, dispensing stops.
2. The dispensed volume flow-rate can be controlled
with the pressure regulation valve (8).

Removing the cartridge

Refer to figure {I} on page II:
1. Release the trigger (7) and press the retract button
(10) until the plungers have moved to the rear stop.
2. Using the cartridge ejector button (5), press the
cartridge out of the cartridge holder and remove the
cartridge upwards.
Dispose of the cartridge and mixer in
accordance with the adhesive / sealant
manufacturer's instructions.
Removing and replacing cartridge holder
and plunger discs
1. Disconnect dispenser from compressed air supply.
2. Squeeze sides of cartridge holder (6) and remove
from top of the dispenser.
3. Remove and replace plunger discs (2) using 4 mm
hex key. Smaller plunger disk is installed on the
lower rod closest to handle (9).
4. Install new cartridge holder (6) from the top of the
dispenser until click. Cartridge ejector button (5)
should be closest to cartridge guide (1).
5. Re-connect compressed air supply.