Use
6.3

Charging refrigerant

I
NOTE
The refrigerant scales must be connected to the AC mains in
order for the solenoid valve to work.
➤ Connect the refrigerant scale to the AC mains using the AC cable
(fig. 1 1, page 2).
➤ Connect a filled refrigerant bottle to the "Input" connection (fig. 2 1,
page 2).
➤ Connect the gas bottle to be filled to the "Output" connection (fig. 2 2,
page 2).
➤ Switch on the scales using the on/off switch (fig. 2 3, page 2).
➤ Place the filled gas bottle on the scale (fig. 5, page 4).
➤ Wait until the scale has determined the current weight and shown this in
the display.
➤ Press the "Charge" button (fig. 3 1, page 3).
➤ Enter the intended charging weight (min 50 g) using the numerical keys.
➤ Press the "Enter" button (fig. 3 6, page 3).
✓ The solenoid valve is opened and the refrigerant is charged.
The solenoid value closes when the selected refrigerant quantity has
been charged.
The scale displays the quantity of refrigerant remaining in the filled
refrigerant gas bottle.
I
NOTE
 Press the "Enter" button fig. 3 6, page 3) to stop a process at
any time. After this, press the "Charge button (fig. 3 1,
page 3), to return to the previous screen.
 If you want to end the charging process before the selected
quantity of refrigerant has been reached, then press the "0"
button. Press the "Enter" button (fig. 3 6, page 3) to exit the
mode.
22
VES100
EN