Caution: PRIOR TO PERFORMING ANY WORK ON THE DISINFECTION
SYSTEM, ALWAYS DISCONNECT THE POWER SUPPLY FIRST.
1. To replace the lamp, there is NO need to disconnect the
system from the water supply, nor to drain the water from
the reactor chamber. Lamp replacement is a quick and
simple procedure requiring no special tools. The UV lamp
must be replaced after 9,000 hours of continuous operation
(approximately one year) in order to ensure adequate
disinfection.
2. Disconnect main power source and allow the unit to power
down. Remove the lamp connector by sliding the
metal retaining ring (Figure 1) away from the body of the
connector. Remove connector and lamp from the reactor
chamber. Separate the lamp from the connector (Figure 2).
Do not twist the lamp from the connector, simply slide the
two apart. Avoid touching the lamp on the glass portion.
Handling the lamp at the ceramic ends is acceptable,
however if you must touch the lamp glass, please use gloves,
or a soft cloth. Fully remove the lamp from the reactor
chamber being careful not to angle the lamp as it is removed
from the chamber. If the lamp is removed on an angle,
pressure will be applied on the inside of the quartz sleeve,
causing the sleeve to fracture.
3. To install a new lamp, first remove the lamp from its
protective packaging, again being careful not to touch the
lamp glass itself. Carefully insert the lamp into the reactor
vessel (actually inside the quartz sleeve) (Figure 3). Insert
the lamp fully into the chamber leaving about two inches of
the lamp protruding from the chamber. Next, attach the
connector to the UV lamp (Figure 2). The connector is
"keyed" and will only allow correct installation in one
position. Ensure the connector is fully seated onto the
UV lamp (Figure 4).
4. Once the lamp is fully seated on the connector, slide the
connector over the aluminum retaining nut. Make sure the
metal retaining ring on the connector is pulled away from
the body of the connector in order that the connector may
slide fully over the retaining nut. Once the connector is
located fully over the retaining nut, slide the metal ring back
in to lock the connector in place (Figure 5). As this connector
is keyed to the reactor chamber, make sure the depression on
the connector (Figure 1) is located over the ground
lug located on the reactor chambe