Water quality is extremely important for the optimum performance of your
UV system. The following levels are recommended for installation:
If your water chemistry contains levels in excess of those mentioned above,
proper pre-treatment is recommended to correct these water problems
prior to the installation of your UV disinfection system. These water quality
parameters can be tested by your local dealer, or by most private analytical
laboratories. Proper pre-treatment is essential for the UV disinfection
system to operate as intended.
I
Y
NSTALLING
• CAUTION, electronic ballast must be connected to a grounded receptacle
and the lamp connector ground wire connected to the stainless steel
reactor chamber.
• The disinfection system is designed to be mounted horizontally or
vertically at the point-of-use or point-of-entry depending on the specific
flow rate of the unit.
Note: The ideal installation is vertical with the lamp connector on top.
This is to prevent water damage from occurring on the lamp pins and
lamp connector.
• The ballast should be mounted either above or beside the reactor
chamber. This will prevent moisture caused by condensation from
entering the ballast enclosure, causing a potential for ballast failure.
• The complete water system, including any pressure or hot water tanks,
must be sterilized before start up by flushing with chlorine (household
bleach) to destroy any residual contamination.
• For safety purposes, the disinfection system should be connected to a
ground fault interrupt circuit.
• The disinfection system is intended for indoor use only, do not install
disinfection system where it may be exposed to the weather.
• Install the disinfection system on cold water line only.
• If treating the entire house, install the disinfection system before any
branch lines.
• A 5 micron sediment filter must precede the disinfection system. Ideally,
the disinfection system should be the last treatment the water receives
before it reaches the faucet.
:
• Iron: < 0.3 ppm (0.3 mg/L)
• Hardness*: < 7 gpg (120 mg/L)
• Turbidity: < 1 NTU
• Manganese: < 0.05 ppm (0.05 mg/L)
• Tannins: < 0.1 ppm (0.1 mg/L)
• UV Transmittance: > 75% (call factory for
recommendations on applications where UVT < 75%)
* Where total hardness is less than 7 gpg, the UV unit should
operate efficiently provided the quartz sleeve is cleaned
periodically. If total hardness is over 7 gpg, the water
should be softened.
UV D
OUR
ISINFECTION
S
YSTEM
4
: