Liberty Pumps 404 Manuel D'installation page 5

Masquer les pouces Voir aussi pour 404:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Pump runs
periodically when
fixtures are not in
use.
Water or soap suds
come out of vent
pipe.
Pump operates
noisily.
PERFORMANCE CURVES AT 80° F WATER TEMP
40
35
30
405 @ 180°F
25
20
15
MODEL 404
10
5
0
0
Check valve was not installed, is
stuck open, or is leaking.
Faucets are dripping.
Vent pipe is too short or too small in
diameter.
Defective switch.
Rate of in-flow exceeds pump
output.
Foreign objects in impeller cavity.
Piping to house structure is too
rigid.
MODEL 404 AND 405
10
20
FLOW (GPM)
Figure 5: Performance curves for 404 and 405.
© Copyright 2017 Liberty Pumps Inc. All rights reserved
Remove and examine for freedom of
operation and proper installation.
Repair faucets to eliminate dripping.
Be sure that an unrestricted vent at least 1-
¼" in diameter is in use.
*Remove tank cover and check that float is
free to move. If build-up restricts float, clean
and reinstall. If defective, replace switch.
Use valve on the inlet to reduce rate of inflow.
*Disassemble the receiver and bottom base
of pump. Remove foreign material.
Reassemble.
Replace a portion of the discharge pipe with
rubber hose to absorb noise.
MODEL 405
30
40
50
60
5

Publicité

Table des Matières
loading

Table des Matières