hestan Aspire Serie Manuel D'installation, D'utilisation Et D'entretien page 16

Masquer les pouces Voir aussi pour Aspire Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
4. IF THE HOOD IS TO BE "BACK VENTED", PROCEED DIRECTLY TO STEP 5.
Consult the connection diagrams (following) for further details on exhaust outlet placement.
EN
Method
Method
Use foil HVAC tape (not grey cloth duct tape) to seal all joints. See "VENT ACCESSORIES" on
page 18 for a listing of available Hestan ducting materials.
TRANSITION HEIGHTS:
TRANSITION HEIGHTS:
Dual Blower (WM2L = 600 CFM): none - 8" round duct will connect directly to the top of the
Single and Dual Blower (WM1L + WM2L = 900 CFM): 6" round duct will connect directly to the
Two Dual Blowers (Two WM2Ls = 1200 CFM):
CONNECTION DIAGRAMS
CONNECTION DIAGRAMS
12
©2020 Hestan Commercial Corporation
(CONT.)
1: Install the duct(s) from the outside of the home down to the location of the exhaust
outlet(s) on the top of the hood or to the transition (if applicable).
If a transition is used, install duct down to the location of the transition outlet plus 1".
This will allow the transition to engage 1" inside of duct.
2: Install the duct(s) from the outside of the home to the ceiling over the exhaust
outlet(s) on the hood. The end of the duct(s) should extend 1" below the ceiling.
hood.
top of the hood; 8" round will connect directly to the top of the hood.
If using the optional multi-blower transition (AKVT6810, sold seperately), a 10"
round duct connects to it 17-1/2" above top of hood. See "VENT ACCESSORIES" on
page 18 for details.
Two 8" round ducts connect directly to the top of the hood.
If using the optional multi-blower transition (AKVT8812, sold seperately), a 12" round
duct connects to it 16-1/2" above top of hood.
See "VENT ACCESSORIES" on page 18 for details.
Connection Diagram (30-36" width)
(Wall Side)
1-3/4"
[4.4 cm]
Electrical
Motor
Cooling
Vent (2)
8" [20.3 cm] Round
WM2L Dual Blower (600 CFM )
5-1/2"
[14 cm]
5-1/4"
[13.3 cm]
Centerline
of Hood
(Top View)