Dometic MPD 93756 Mode D'emploi page 3

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• For an external electrical source, ground this unit in accordance with
National Electrical Code ANSI/NFPA70.
Your Dometic gas water heater is now ready for operation. Continue to
HOW TO OPERATE YOUR WATER HEATER.
Electronic Ignition
Electronic Ignition WIRING INSTRUCTIONS.
continue to
Pilot Relight continue to Pilot Relight WIRING INSTRUCTIONS.
For HEAT EXCHANGE continue —
1. Push 5/8˝ dia. 2 or 3 coolant system hose with SAE 053 A Type
"E"clamp attached (
6-E) onto heat exchange tube as far as
FIG
possible (
6-B).
FIG
2. Spread hose clamp and slide toward heat exchange unit past annular
groove (
6-C) and release.
FIG
3. Continue to HOW TO OPERATE YOUR WATER HEATER and/or Electronic
Ignition OPERATION.
For COMBINATION GAS/ELECTRIC MODELS continue —
This water heater is designed to operate with gas, electricity, or a
combination of both.
Provide adequate clearance at rear of unit for service of water
connections and operation of manually re-setable high temperature limit
switch on combination gas/electric units.
1. Follow GENERAL INSTALLATION instructions.
: All wiring must comply with applicable electrical codes.
NOTE
PRODUCT DAMAGE
• When using Romex
with a bare earth ground, take care to position
®
ground wire so it does not contact the heating element terminals.
• Use electrical metallic tubing, flexible metal conduit, metal clad cable,
or nonmetallic-sheathed cable with grounding conductor. Wire must
have a capacity of 1500 watts or greater. The wiring method must
conform to applicable sections of article 551 of National Electrical
Code ANSI/NFPA 70.
2. Refer to Wiring Diagram. Make 120 VAC electrical connections from
junction box on back of unit.
a. Connect hot lead to (1) Black.
b. Connect common lead to (2) White.
c. Connect ground wire from electrical service to (3) green ground
lead in junction box 3. Place switch in "OFF" position.
• When a cord and plug connection to the power supply are used on
water heater, power cord must be UL listed as suitable for damp
locations, hard or extra hard usage. It must be a flexible cord such as
type S, SO, ST, STO, SJ, SJT, SJTO, HS or HSO cord as described in
National Electrical Code, ANSI/NFPA 70. The length of external cord to
water heater, measured to face of attachment plug, shall be no less
than 2 feet nor more than 6 feet. Supply cord must be a minimum of
14 AWG and attachment plug must be rated at 15 amps.
ELECTRICAL DAMAGE
Label all wires before disconnecting when servicing controls.
Verify proper operation after servicing.
Operation using gas continue to HOW TO OPERATE YOUR WATER HEATER,
electrically continue to COMBINATION Gas/Electric OPERATION.
ELECTRONIC IGNITION - WIRING INSTRUCTIONS
1. Install unit according to GENERAL INSTALLATION instructions.
: It is recommended unit be connected directly to a 12V DC battery
NOTE
or to filtered side of an AC/DC converter. Avoid connections to
unfiltered side of an AC/DC converter whenever possible. Use a
minimum of 18 gauge wire, UL and CSA listed.
Refer to WIRING DIAGRAM. Install remote switch in a convenient
location. Position wall plate with letters up. Before making
connections turn switch OFF. The switch is off when the button is
depressed towards terminal see wiring diagram.
CAUTION
CAUTION
2. Installing wires:
a. blue lead to switch terminal (6) on indicator light of switch
b. terminal (4) on indicator light of switch to negative battery terminal
c. green lead to negative battery terminal
d. brown lead on water heater to terminal (3) on switch
e. terminal 2 on switch to positive battery terminal.
3. Read ELECTRONIC IGNITION OPERATION.
PILOT RELIGHT - WIRING INSTRUCTION
1. Install unit according to GENERAL INSTALLATION instructions.
2. Refer to Wiring Diagram. Use 18 gauge wire, UL/CSA listed.
3. Read PILOT & PILOT RELIGHT OPERATIONS.
CONSUMER SAFETY WARNINGS
EXPLOSION OR FIRE
store or use gasoline or other flammable vapors and liquids in
• DO NOT
the vicinity of this or any other appliance.
Should overheating occur, or gas supply fail to shut off, turn OFF
manual gas control valve to appliance, or turn gas OFF at the LP
tank. On ELECTRONIC IGNITION MODEL turn operating switch to OFF
position and remove red wire from left hand terminal of ECO switch
or turn gas OFF at the LP tank.
Use with LP gas only.
Shut off gas appliances and pilot lights when refueling.
On PILOT RELIGHT MODELS, turn off the ignition module when
refueling gasoline tanks or LP tanks.
Turn gas OFF at the LP tank when vehicle is in motion. This disables
all gas appliances and pilot lights. Gas appliances must never be
operated while vehicle is in motion. Unpredictable wind currents
may be created which could cause flame reversal in the burner
tube, which could result in fire damage. The thermal cut off fuse
could also be unnecessarily activated resulting in a complete
shutdown of the water heater requiring replacement of the thermal
cut off. See maintenance of electronic ignition water heaters for
further explanation of the thermal cut off.
LP tanks must be filled by a qualified gas supplier only.
HOW TO OPERATE YOUR WATER HEATER
Do not smoke or have any flame near an open faucet.
If water heater has not been used for more than two weeks, hydrogen
gas may form in water line. Under these conditions to reduce the risk
of injury, open hot water faucet for several minutes at kitchen sink
before you use any electrical appliance connected to hot water system.
If hydrogen gas is present, you will probably hear sounds like air
escaping through the pipe as water begins to flow.
SCALDING INJURY
• Do not tamper with pilot orifice.
PRODUCT FAILURE
• Do not operate without water in tank.
PILOT OPERATION
1. Turn gas control valve knob (
2. Wait at least five minutes to allow accumulated gas in burner
compartment to escape.
3. Water heater may be equipped with a White Rodgers
Robertshaw Unitrol
Control.
®
3
WARNING
CAUTION
FIRE
WARNING
CAUTION
7-B or
8-B) to OFF position.
FIG
FIG
or
®

Publicité

Table des Matières
loading

Table des Matières