Thermador HDDW 36DS Mode D'emploi page 6

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PRIOR TO INSTALLATION
For optimum extractor hood efficiency:
Short, smooth duct pipe.
As few bends in the ducting as possible.
Diameter of ducting to be as large as
possible and no tight bends in ducting.
If long, rough exhaust-air ducting, many ducting
bends or smaller pipe diameters are used, the air
extraction rate will no longer be at an optimum
level and there will be an increase in noise.
IMPORTANT: The manufacturer of the extractor
hood accepts no liability for complaints which can
be attributed to the design and layout of the
ductwork.
Round pipes:
We recommend
Internal diameter: 6".
Flat ducts must have an internal cross-section that
equates to that of round pipes.
There should be no sharp bends.
l 6" approx. 28.3 inches
If pipes have different diameters:
Insert sealing strip.
For exhaust-air mode, ensure that there is an
adequate supply of fresh air.
CONNECTING A l 6" EXHAUST-AIR DUCT:
Mount the duct directly onto the air outlet on the hood.
2
PRIOR TO INSTALLATION
Step 2: PREPARING THE WALL
The wall must be flat and perpendicular.
Ensure that the wall is capable of providing a firm hold
for mounting screws and plugs.
Weight in kg: 23.4.
PAGE 4

Publicité

Table des Matières
loading

Table des Matières