Ground connections and equipotential bonding
 The appliance must be connected to the ground circuit using the terminals marked by the symbol located next to the
connection terminals.
 The metal structure of all the electrical appliances must also be connected to the ground circuit using the terminals
marked by the symbol
SETTING UP
Testing the electrical system
 Switch on the appliance following the instructions for use and cheek the operation of the control devices and well
heating elements.
 Test the various operating temperatures.
 The appliance is fitted with an internal safety thermostat for each well that cuts off the electrical power supply to the
heating elements if the main thermostat malfunctions.
 If necessary, consult the Troubleshooting guide to identify the problem.
Testing the rated thermal power
 Always cheek the thermal power of the appliance after installation and following maintenance work.
 The rated thermal power is indicated in the "Technical data" table.

TROUBLESHOOTING GUIDE

The well heating elements do not heat up
 Check the fuses.
 Main power switch not ON.
 Low voltage or incorrect electrical connection.
 Switch faulty.
 Temperature control thermostat faulty.
 Main temperature control thermostat faulty, causing the safety thermostat to cut in (reset).
 One or more well heating elements incorrectly connected or burnt out (replace faulty heating element).
The temperature control is difficult or impossible to regulate
 Temperature control thermostat faulty.
 One or more well heating elements incorrectly connected or burnt out (replace faulty heating element).
IMPORTANT : Before carrying out maintenance work or repairs, disconnect the appliance from the power supply at
the isolating switch.
Temperature control thermostat, safety thermostat
 Remove the upper control panel.
 Open the appliance doors and drain the oil from the well in question (see "Draining off the oil").
 Detach the bulb from the thermostat fixed to the heating element by special support brackets.
 Disconnect the electrical connections.
 Replace the part.