2.2
E
XTRAIT DES PARAMETRES PRINCIPAUX
N° par.
Désignation
P 3.1.1.1
Motor Nominal Volt
P 3.1.1.2
Motor Nominal Freq
P 3.1.1.3
Motor Nom Speed
P 3.1.1.4
Motor Nom. Current
Motor Cos Phi
P 3.1.1.5
(Power Factor)
P 3.1.1.6
Motor Nom. Power
P 3.1.3.1
Motor Current Limit
P 3.2.5
Stop Function
P 3.2.6
I/O A Start/Stop Logic
P 3.2.7
I/O B Start/Stop Logic
P 3.3.1.1
Min. Frequency Reference
P 3.3.1.2
Max. Frequency Reference
P 3.3.1.5
I/O Control Ref A Selection
P 3.3.1.8
Keypad Reference
P 3.3.3.10 Preset Freq Selection 0
P 3.3.3.11 Preset Freq Selection 1
P 3.4.1.2
Acceleration Time 1
P 3.4.1.3
Deceleration Time 1
P 3.5.1.2
Control Signal 2 A
P 3.5.1.4
Control Signal 1 B
P 3.5.1.7
I/O B Control Force
P 3.5.1.8
I/O B Reference Force
P 3.5.1.11 External Fault Close
P 3.5.1.13 Fault Reset Close
P 3.5.1.21 Preset Freq Selection 0
P 3.5.1.22 Preset Freq Selection 1
P 3.9.2.2
Ambient Temperature
Motor Thermal Time
P 3.9.2.4
Constant
P 3.9.3.1
Motor Stall Fault.
P 3.9.3.2
Stall Current
P 3.9.3.3
Stall Time Limit
P 3.9.3.4
Stall Frequency Limit
P 3.13.1.4 Process Unit Selection
P 3.13.1.5 Process Unit Min
P 3.13.1.6 Process Unit Max
P 3.13.2.6 Setpoint Source 1 Selection
Valeur
id
230
110
50
111
1370
112
1,9
113
0,74
120
0,37
116
3,7
107 Maximum current supplied by the drive
1 = Ramping
506 Stop following ramp (id 103)
0 = Forw/Back
300 Logic selection A On / Off
0 = Forw/Back
363 Logic selection B On / Off
20
101 Adjust the minimum frequency
50
102 Adjust the maximum frequency
PID
117 Choice of reference
20
184 Indicates the keypad reference
DigIN Slot A.5
419
DigIN Slot 0.1
420
10
103
15
104
DigIN Slot 0.1
404
DigIN Slot A.4
423
DigIN Slot A.6
425
DigIN Slot A.6
343
DigIN Slot A.2
405
DigIN Slot A.3
414
DigIN Slot A.5
419
DigIN Slot 0.1
420
40
705
10
707
3 = Fault (Stop by
709 Allows freewheel stop in case of engine stall
coasting)
1,9
710
5
711 Time delay to enter engine timing
20
712
bar 1036 Unit selection
0 1033
10 1034
AI1
332 Selecting the setpoint source
Page 25
Observations
See motor platename
Adjust the ramps to your needs
Ambient temperature threshold around the motor.
To deactivate if engine temperature sensor.
Constant warm-up time. To disable if engine
temperature sensor
Motor current limit beyond which a stall occurs.
Indicate the rated current of the motor
Frequency below which the engine setting can
intervene
Minimum value of your return to the defined unit
(id1036)
Maximum value of your return to the defined unit
(id1036)