1.4
S
PECIFIC PARAMETERS TO THE STANDARD OPERATING MODE WITHOUT SENSOR
N° par.
Désignation
P 3.2.4
Start
Function
P 3.3.1.5
I/O Control
Reference
A Selection
P 3.5.2.1.2
AI1 Signal
Filter Time
P 3.5.1.2
Control
Signal 2 A (s)
P 3.5.1.12
External
Fault Open
P 3.5.1.21
Preset
Frequency
Selection 0
P 3.5.3.2.1
RO1
Function
P 3.5.3.2.4
RO2
Function
P 3.1.2.6
Motor
Switch
P 3.1.2.3
Switching
Frequency
(kHz)
P 3.9.1.4
Undervoltag
e Fault
P 5.8.1.1
Protocole
P 5.8.3.1.1
Adresse
esclave
P 5.8.3.1.2
Débit en
bauds (bps)
P 5.8.3.1.3
Type de
parité
P 5.8.3.1.4
Bits d'arrêt
P 5.8.3.1.5
Tempo.
communic.
(s)
P 5.6.1.1
Fan Control
Mode
P 3.2.6
I/O A
Start/Stop
Logic
P 3.5.1.13
Fault Reset
Close
Valeur
Min
1 = Flying
Ramping
start
4 = AI1
0 = PC
1
0
DigIN
N/A
Slot0.1
DigIN Slot
N/A
A.2
DigIN
N/A
SlotA.3
3 = General
No used
fault
2 = Run
No used
1 = Enabled 0 =
Disabled
6
1,5
1 = Fault
0 = Fault
not stored
stored in
in
history
history
4 =
Aucun
ModBus
protocole
RTU
12
1
9600 =
300
9600
3 = Aucun
Pair
1 = 1
1
5
0
1 =
0 =
Optimised
Always on
0 =
0 =
Forward/
Forward/
Backward
Backward
DigIN
N/A
Slot0.1
Page 22
Max
Default
Flying start
Ramping
20 = Block
AI1+AI2
Out.10
300
0,1
N/A
DigIN
SlotA.2
N/A
DigIN
Slot0.2
N/A
DigIN
SlotA.4
AHF Cap
Run
Disconnect
Inv
AHF Cap
Défault
Disconnect
Inv
1 = Enabled
0 =
Disabled
10
0
1 = Fault
0 = Fault
not stored
stored in
in history
history
15
Aucun
protocole
247
1
230400
9600
Aucun
Aucun
2
2
65535
10
1 =
0 =
Optimised
Always on
4 = start /
0 =
reverse
Forward/
Backward
(edge)
N/A
DigIN Slot
A.6
ID
Observations
505
Start Function
117
source of the frequency
reference when the control
source is I / O A.
378
filter the disturbances of the
analog input signal.
404
logic input signal (control
signal 2) which controls the
start
and
stop
converter when the control
source is I / O A (AR).
406
logic
input
activates an external fault.
419
logic
input
selecting
the
frequencies.
11001
function or signal connected
to the relay output.
11004
function or signal connected
to the relay output.
653
activation of the function
Interrupt mot.
601
frequency of switching of the
frequency converter.
727
Undervoltage faults must or
may not be recorded in the
fault history.
2208
Protocole
2320
Adresse esclave
2378
Débit en bauds
2379
Type de parité
2380
Bits d'arrêt
2321
Tempo. communic.
2377
Fan Control Mode
300
controls the start and stop of
the converter using logic
signals.
414
logic
input
resetting all active faults.
of
the
signal
that
signal
for
preset
signal
for
Dec 2017