Operating Instructions

Normal Operating Sounds

Certain sounds may be made when air conditioner runs,
especially in a cooling mode. Sounds may include:
Water splashing onto condenser; caused by slinger
ring attached to condenser fan. Slinger ring picks up
water (condensate) in base pan and sprays it on
condenser to increase efficiency of unit.

Care and Maintenance

!
WARNING
To avoid death or personal injury due to electrical
shock, turn off fan control and unplug power cord
before cleaning or performing maintenance on this
device.

Maintenance Schedule

Kenmore Room Air Conditioners are designed and
manufactured to provide years of dependable service
when properly cared for and maintained.
Maintenance Required
Inspect/clean air filter.
Inspect/clean air discharge
louvers, return air grille, and
electronic control.
Inspect louvers on outer case
for obstructions.
Inspect condenser coil.
Inspect evaporator coil.
Inspect outer case for
signs of damage.
Inspect/clean base pan.
Table 2. Maintenance Schedule
Procedure
Remove air filter and inspect. Clean if required; replace.
NOTE: Never operate air conditioner with filter removed.
Inspect air discharge louvers, return air grille, and electronic
control for dust and dirt accumulation. Clean, if necessary.
NOTE: Inspect more often in dusty environments.
Inspect louvers on outer case and remove any obstructions.
Inspect condenser coil for dirt, bent fins, and other
obstructions. Clean/repair, if necessary.
NOTE: Inspect more often in dusty environments.
Inspect evaporator coil for dirt, bent fins, and other
obstructions. Clean/repair, if necessary.
NOTE: Inspect more often in dusty environments.
Inspect interior and exterior of outer case for scratches,
paint blisters, rust, and other damage. Repair as necessary.
NOTE: Inspect more often in salty or other corrosive
environments.
Inspect base pan for scratches, blisters, rust, dents, and other
damage. Repair as necessary. Clean condensate drain
passages of any accumulated material.
NOTE: In areas of excessive humidity, use algicide (algae
inhibitor) in base pan to help reduce algae build-up.
23
Compressor cycles frequently. High efficiency
compressors used in new Kenmore Room
AirConditioners run more frequently but for shorter
periods and consume less energy than older, less
efficient compressors.
Airflow from air discharge vent. If sound is distracting,
try adjusting louvers on discharge vent, moving objects
that may be obstructing airflow, or reducing fan speed.
Maintenance Schedule (below) shows maintenance
required to keep unit operating at peak efficiency. Most
maintenance can be performed using common tools,
equipment, and products. See Maintenance Procedures
(beginning on page 24).
Large maintenance tasks, such as washing condenser
and evaporator coils, should performed by an authorized
Sears servicer (at owner's expense). Call 1-800-4-88-
1222 for location of a local authorized Sears Service
Center.
Frequency
Weekly
Weekly
Monthly
Annually
Annually
Annually
Annually