Alarm - Fault Indication

Error messages

1
Display
E2
E3
E4
E
E5
room temperature
water temperature
water temperature
Room temperature
Water temperature
Meaning
too high
too high
too low
sensor failure
sensor failure
When alarm occurs, the error code will be displayed.
The alarm sound will be suspended by pressing any button, but the alarm code remains on display until the alarming condition is eliminated.
Troubleshooting
Failure
Fault Cause
Approach
Check and ensure the power interface and the
Machine turned on but not receiving power
Power cord is not plugged in place
power plug is plugged in place and in good
contact.
PuII out the fuse box from the power supply
interface of the chiIler, check the fuse, replace with
spare fuse, if necessary and check whether the
Fuse burnt-out
power supply voltage is stable. Check and ensure
the power interface and the power plug is plugged
in place and in good contact.
Flow AIarm (red LED on) -
Check the water level gauge, add water
no water fl ow despite everything being
Water IeveI is too low
until the level is in the green area. Also check
connected properly
whether water circulation tube leaks
Water circulation tubes are blocked
Check water circuIation tubes. They should not
or tubes are deformed by bending
be bent or twisted.