Kärcher HDS 9/16-4 ST Gas Mode D'emploi page 18

Masquer les pouces Voir aussi pour HDS 9/16-4 ST Gas:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Anti-calcification measures
b
c
a
 Remove spring (c) from the lid support (b) of the softener tank
(a).
 Fill the tank with Kaercher softener liquid RM 110 (Order no.
2.780-001).
DANGER
Dangerous electrical voltage! Setting may only be done by an
electrician.
 Determining the hardness of tap water:
– through the public water supply works,
– using a hardness tester (order no. 6.768-004)
 Remove the appliance cover.
 Open the switch box at the operating panel.
 Set the speed potentiometer (a) according to the water hard-
ness. You can refer to the correct setting in the table.
Example:
For a water hardness of 15 °dH, set 6 on the value scale of the
speed potentiometer. This results in a pause of 31 seconds, i.e.
the solenoid valve will open briefly every 31 seconds.
Water hardness (°dH)
Scale on the speed potenti-
ometer
Pause (in seconds)
a
5
10
15
20
8
7
6
5
50
40
31
22
Adjusting the operations stand-by time
The operations stand-by time is set on the larger plate on the left
side-wall of the electrical cabinet.
The operations stand-by time is set in the factory to a minimum
time of 2 minutes and can be increased to a maximum time of 8
minutes.
25
4,5
16
17
-
EN
S2
8 7 6 5 4 3 2 1
min.
max.
39

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hds 12/14-4 st gasHds 12/14-4 st gas lpg1.251-9001.251-9011.251-902

Table des Matières