Packing List; Installation; Wiring - Retekess T-AC03 Mode D'emploi

Masquer les pouces Voir aussi pour T-AC03:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Packing List

Name
Keypad
User manual
Screw driver
Rubber plug
Self tapping screws
Star screws
Please ensure that all the above contents are correct. If any are missing please notify the supplier
of the unit.

Installation

• Remove the back cover from the keypad using the supplied special screw driver
• Drill 2 holes on the wall for the Self tapping screws and I hole for the cable
• Put the supplied rubber bungs to into the two holes
• Fix the back cover firmly on the wall with 2 Self tapping screws
• Thread the cable through the cable hole
• Attach the keypad to the back cover

Wiring

Colour
Function
Pink
BELL_A
Pale blue
BELL_B
Green
White
Grey
ALARM
Yellow
OPEN
Brown
Red
Black
Blue
Purple
Orange
Quantity
1
1
1
2
2
1
Description
Doorbell button one end
Doorbell button to the other end
D0
WG output D0
D1
WG output D1
Alarm negative(alarm positive connected 12 V+)
Exit button one end(the other end connected GND)
D_IN
Magnetic switch one end(the other end connected GND)
12V+
12V + DC Regulated Power Input
GND
12V - DC Regulated Power Input
Relay normally-on end(Connect positive electric lock "-")
NO
COM
Relay Public end, connect GND
NC
Relay Closed end(connect negative electric lock "-")
Remarks
Φ20mm×60mm,Special for keypad
Φ6mm×30 mm , used for fixing
Φ4mm×28 mm , used for fixing
Φ3mm×6mm, used for fixing
2

Publicité

Table des Matières
loading

Table des Matières