Installation, Relocation And Inspection; Specifications - Mitsubishi Electric MSZ-FA25VA Notice D'utilisation

Masquer les pouces Voir aussi pour MSZ-FA25VA:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 34

INSTALLATION, RELOCATION AND INSPECTION

Installation place
Avoid installing the air conditioner in the following places.
• Where flammable gas could leak.
CAUTION:
Do not install the unit where flammable gas could leak.
If gas leaks and collects around the unit, it may cause an explosion.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sulfide gas is generated such as a hot spring.
• Where oil is splashed or where the area is filled with
oily smoke.
• Where there is high-frequency or wireless equipment.
WARNING :
If the air conditioner operates but does not cool or heat (depending on model) the room, consult your dealer since
there may be a refrigerant leak. Be sure to ask the service representative whether there is refrigerant leakage or not
when repairs are carried out.
The refrigerant charged in the air conditioner is safe. Refrigerant normally does not leak, however, if refrigerant gas
leaks indoors, and comes into contact with the fire of a fan heater, space heater, stove, etc., harmful substances will
be generated.
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
WARNING :
The customer should not install this unit.
If installation is done incorrectly, it may cause a fire, an electric shock, or injury from the unit falling, water leaking, etc.
Do not use intermediate connection of the power supply cord or the extension cord and do not connect many
devices to one AC outlet.
A fire or an electric shock may result from poor contact, poor insulation, exceeding the permissible current, etc.
Consult your dealer.

SPECIFICATIONS

Set name
Model
Indoor
Outdoor
Function
Power supply
Capacity
kW
Input
kW
Indoor
kg
Weight
Outdoor
kg
Refrigerant filling capacity (R410A)
kg
Indoor
IP code
Outdoor
Permissible ex-
LP ps
MPa
cessive operat-
ing pressure
HP ps
MPa
Indoor (Super High/
dB(A)
High/Med./Low)
Noise level
Outdoor
dB(A)
The installation location of the outdoor unit should
be at least 3 m away from the antennas for TV sets,
radios, etc. In areas where the reception is weak,
provide greater space between the outdoor unit and
Inverter-type
the antenna of the affected device if operation of the air
fluorescent lamp
conditioner interferes with radio or TV reception.
To prevent the effects
of a fluorescent lamp,
keep as far apart as
possible.
Keep a space
to prevent the
picture
distortion or
the noise.
1 m
100 mm or
or more
more
1 m
or more
TV
Cordless
phone or
Portable
3 m
phone
or more
Radio
MSZ-FA25VA(H)
MSZ-FA35VA(H)
MSZ-FA25VA
MSZ-FA35VA
MUZ-FA25VA(H)
MUZ-FA35VA(H)
Cooling
Heating
Cooling
~ /N, 230V, 50Hz
2.5
3.2
3.5
0.595
0.735
0.935
10
33
37
0.90
1.05
IP 20
IP 24
1.64
4.15
42/36/29/21
42/36/29/22
46
47
CAUTION:
• Earth the unit.
Do not connect the earth to a gas pipe, water pipe, lightning rod or the earth of a telephone. If the earthing is incorrect,
it may cause an electric shock.
wall, etc.
• Install an earth leakage breaker depending on the place where the air conditioner is to be installed (humid places, etc.).
If the earth leakage breaker is not installed, it may cause an electric shock.
Well-
ventilated
dry place
Inspection and maintenance
• When the air conditioner is used for several seasons, the capacity may be lowered due to dirt inside the unit.
• Depending on the condition, an odor may be generated or dehumidified water may not drain out smoothly due to dirt,
200 mm or
more
dust, etc.
• It is recommended that the unit be inspected and maintained (charged) by specialist in addition to normal maintenance.
Consult your dealer.
Operating sound considerations
• Do not put an object around the air outlet of the outdoor unit. This may lower the capacity or increase the volume of the
operating sound.
• If an abnormal sound is heard during operation, consult your dealer.
Relocation
• When the air conditioner is to be removed or re-installed because of rebuilding, moving, etc., special techniques and
work are required.
WARNING :
Repairs or relocation should not be done by the customer.
If this is done incorrectly, it may cause a fire, an electric shock, or an injury from the unit falling, water leaking, etc.
Consult your dealer.
Disposal
To dispose of this product, consult your dealer.
NOTE:
1. Rating condition
Cooling —
Indoor
: 27°C DB, 19°C WB
Heating
Outdoor : 35°C DB
Heating —
Indoor
: 20°C DB
4.0
Outdoor : 7°C DB, 6°C WB
0.995
2. Guaranteed operating range
Indoor
32°C DB
Upper limit
23°C WB
Cooling
21°C DB
Lower limit
15°C WB
27°C DB
Upper limit
Heating
20°C DB
Lower limit
48
If you have any questions, consult your dealer.
Outdoor
MUZ-FA25/
MUZ-FA25/
35VA
35VAH
46°C DB
46°C DB
-10°C DB
-10°C DB
24°C DB
24°C DB
18°C WB
18°C WB
-10°C DB
-20°C DB
-11°C WB
-21°C WB
17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Msz-fa35va

Table des Matières