7.1 SELECTING AC INPUT VOLTAGE
The charger is pre-set to operate from input AC voltage of 120 VAC, 60 Hz. To operate the
charger from AC input voltage of 230 VAC, 50 Hz, change the internal setting as follows:
1. Remove the side plate that has the power cord entry by unscrewing 4 screws
2. Remove the Voltmeter and the Ammeter on the top central plate by prying up the
bottom edges of the meters with a broad, flat screw driver and by pushing the meters
up from the bottom of the plate (these are snap fitted). Remove the connecting wires
and mark them. Note the polarity for connecting back in proper polarity. The meter
terminals are marked Positive (+) and Negative (-). Thicker wires are for the Ammeter
and thinner are for the Voltmeter
3. Gently slide the center top cover plate out. Note and mark its orientation for
correct re-fitting
4. Locate Yellow loop of jumper wire with quick female disconnect. In the pre-set
120 VAC condition, this jumper wire is shorting the male vertical pins marked "C" and
"D" and "115V". Pull any one end of this female disconnect upwards to disconnect
shorting between "C" and "D". Insulate this end with insulating tape. The unit is now
set for "230 VAC"
5. The 120 VAC version has a soldered 20A fuse on the AC side. When converting
120 VAC version unit for 230 VAC operation, there is no need to replace the 20A fuse
6. Replace the AC plug of the power cord with a suitable 3 pin grounded plug to mate
with the 230 VAC outlet.
!
CAUTION!
The new plug should have 3 poles i.e. Line (L), Neutral (N) and Earth ground.
Color code for the power cord conductors is:
- Line (L) - Black
- Neutral (N) - White
- Earth ground - Green
7.2 CONNECTING BATTERIES OR OTHER DC LOADS
As shown in Fig. 7.1 and 7.2, the output of the charger has a common Negative (-) con-
nector and 2 Positive connectors for connection of 2 banks of batteries. Each Positive
connector has its own internal Isolating Diode, which works as a battery isolator. If more
than one bank of batteries is connected, these will be charged at the same time as long
as the AC power is available to the charger. The maximum charging current of 80A (Full
Power Mode)/ 40A (Half Power Mode) for SEC-1280UL and 40A (Full Power Mode)/ 20A
(Half Power Mode) current for SEC-2440UL will be shared among the connected banks
of the batteries depending upon their discharged states. In case the AC power fails or
if there is no output from the charger, the Isolating Diodes will prevent charging / dis-
charging among the batteries connected to the banks.